Installation and user instructions
1. Where to install
The inverter should be installed in a location that meets the following requirements:
Dry – Do not allow water to drip or splash into the inverter.
Cool – Ambient air temperature should be between -20 and 40 .
℃
℃
Safe – Do not install into a battery compartment or other areas where flammable fumes
may exist, such as fuel storage areas or engine compartments.
Ventilated – Allow at least one inch of clearance around the inverter for air flow. Ensure
the ventilation openings on the rear and front of the unit are not obstructed.
Dust – Do not install the Inverter in dusty environments. This dust can be pulled into the
unit when the cooling fan is operating.
Away from batteries- Do not mount the Inverter where it will be exposed to corrosive
gases produced by batteries.
2. Installation
2-1. Before installing the inverter, make sure the main switch is in “OFF” position.
2-2. DC Input connection:
We recommend the DC cable length should be not longer than 6 feet/1.8m, and the
recommended gauge according to below indicated table:
Model No.
Wire (mm
2
)
SI1500-24110/24230
25
SI1500-48110/48230
16
Crimp the DC cable with the ring terminals which are included in the package of the
inverter, then fasten these to the inverter DC connector with a screwdriver.
22
ENG
All manuals and user guides at all-guides.com