Accutome 4Sight Service Manual Download Page 5

Accutome 4Sight

 

Service Manual

 

Page 5 of 5 

 

 

 

 

Service and Repair

 

 

Before returning instruments for service or repair, contact the Accutome Technical 
service Group for a Return Authorization (RA) number. 

 

Toll Free (in USA): 1-800-979-2020 
Tech Service: 1-610-889-0200 
Fax: 1-610-889-3233 

 

After receiving authorization, print the RA number on the outside of the package and 
send the instrument to: 

 

Technical Service Group 
Accutome, Inc. 
3222 Phoenixville Pike 
Malvern, PA 19355 

 
 

Replacement Parts

 

 

The table below lists user replaceable items that are available from Accutome, Inc. 
Please be sure to use the Accutome part number for the item when placing an order. 

 

4Sight Replacement Parts

 

 

Description

 

Accutome Part No.

 

 

 

Standard Parts

 

 

Control Unit 

24-8000 

4Sight A-scan Probe 

24-8000A 

4Sight B-scan Probe  

24-8000B 

  4Sight Pachymeter Probe 

  24-8000P 

  Footswitch 

  8000-0260 

  User Manual 

  24-8016 

Keyboard 

  8000-0270 

Mouse 6100-0020 

6100-0020 

 

 

 

 

 

Summary of Contents for 4Sight

Page 1: ...Accutome Inc 4Sight Service Manual P Ns 24 8000 ...

Page 2: ...070943 and Accupach Pachymeter K042752 devices into a combined stand alone platform The device performs axial length measurements corneal thickness measurements and images the internal structure of the eye using these 3 modalities The 4Sight is a stand alone system which runs on a Windows 8 platform consisting of a 4Sight control unit transducers footswitch and keyboard ...

Page 3: ...mplete 4Sight system and the larger environment is beyond the scope of this section The 4Sight application is written in Microsoft C NET version 4 0 The WinUSB device driver is used to connect USB based devices such as the B Scan device with the Windows OS Software Context Diagram Win USB Driver Microsoft Windows OS USB Footswitch Mass Storage A scan B scan Pachymetry Display device LCD CRT 4Sight...

Page 4: ...ty selected Re check USB connection Contact Accutome if problem persists Error deleting snapshots Make sure snapshot files are not in use by another program or open Close if open and re try Entered value out of range invalid Re check values being entered to make sure they are correct Failed to initialize DICOM There may be an issue with the DICOM connection Re try connecting the device to the serv...

Page 5: ...e and send the instrument to Technical Service Group Accutome Inc 3222 Phoenixville Pike Malvern PA 19355 Replacement Parts The table below lists user replaceable items that are available from Accutome Inc Please be sure to use the Accutome part number for the item when placing an order 4Sight Replacement Parts Description Accutome Part No Standard Parts Control Unit 24 8000 4Sight A scan Probe 24...