Accu-Steam Gas Griddle
11
9. Is an external gas regulator connected to the griddle (Circle Y/N)
Y
N
10. What is the Length and Width of the Gas Supply Line L W
11. Gas Pressure measurements
Natural Gas: Static WC Dynamic WC
Dynamic pressure should be 5”WC
(Regulator valve pressure tap - 1/8NPT)
Propane: Static WC Dynamic WC
Dynamic pressure should be 10”WC
(Regulator valve pressure tap -1/8NPT)
12. What is the measured flame sense on the unit when the main burners are lit?
DCuA (microampere)
ACCU-STEAM Gas Griddle Start-Up Form (continued)
Temperature Verification
1. What is the customers normal operating temperature for the Griddle?
°F
2. Using a
weighted contact temperature probe with digital thermometer
, does the
surface temperature match the set temperature on the griddle controller? (Circle
Y/N)
Y
N
3. Does the griddle heat light cycle ON/OFF once the surface temperature has met the
set temperature? (Circle Y/N)
Y
N
4. Bring the griddle to 350°F and allow it to cycle twice. Take 9 temperatures across the surface of
the unit in grid form and record (the temperatures should be consistent to ±10°F):
LEFT
MIDDLE
RIGHT
5. Does the unit operate correctly for 15 minutes after unit has reached temperature?
(Circle Y/N)
Y
N
I accept this Start-up form as complete and accurate:
Signed: Restaurant Management
Print Name:
Date: / /