SP8016-1005
ACCU-STEAM SERVICE MANUAL
PAGE 7
REMOVAL AND INSTALLATION
ThERMOSTAT
WARNING - ALL THERMOSTATS MUST BE CALIBRATED TO 400 °F, ( +1
°F,/-4 °F,
)
Unplug the unit
1.
Remove the three screws from the front door panel and drop the panel down.
2.
Remove the knob and retaining nut from the front of the panel.
3.
Disconnect the wires from the pins on the thermostat. Note their locations.
4.
Reassemble in reverse order.
5.
Note: Units with serial numbers 2611 to 7550 have a type K thermostat and thermocouple.
(red and yellow leads) Serial numbers 7551 and above have a RTD thermostat and probe.
(two red leads). When replacing a thermostat, always use a RTD thermostat and probe.
CALIBRATION POT
K Type Temperature Controller - P/N AT0E-2559-3
This was replaced by the RTD
Controller P/N AT0E-2559-6 &
Thermocouple P/N AT0E-2885-3
Must be used on all older series
griddles with the welded in
thermocouple
RTD Type Temperature Controller - P/N AT0E-2559-6
MUST USE RTD THERMOCOUpLE
p/N AT0E-2885-3
Calibration Pot