AccuStream Abrasive Regulator II Manual Download Page 1

13096 Abrasive Regulator II 

 

 

 

 

ABRASIVE

 

REGULATOR II

 

 
 

 
 
 
 

Summary of Contents for Abrasive Regulator II

Page 1: ...13096 Abrasive Regulator II ABRASIVE REGULATOR II ...

Page 2: ...gulator Installation 2 Location 2 Attaching the Regulator to the Machine 2 Connecting the Metering Regulator 3 Abrasive Delivery from the Pot to the Regulator 3 2 2 Regulator Startup 4 Metering Regulator Flow Rate 4 Moisture or Water 5 Disassembly and Reassembly 6 3 Drawings and Parts Lists 7 ...

Page 3: ...ct Information and Customer Technical Service At AccuStream your purchase is only the beginning of our commitment to help you succeed We believe that what happens after the sale is just as important as what happens before Customer Service Representatives are available to take your calls Monday through Friday 7 00 AM to 5 00 PM CST If you need service after hours AccuStream is also on call 24 hours...

Page 4: ...h to keep the regulator out of the spray back area from the cutting head and within reach for adjusting the abrasive flow rate Attaching the Regulator to the Machine 1 Remove the back mounting plate from the regulator Use the mounting plate to position and drill mounting holes on the machine NOTE The holes on the mounting plate are positioned 2 inches 50 8 mm on center from each other and counter ...

Page 5: ...f the regulator Abrasive Delivery from the Pot to the Regulator The hose from the pot to the metering regulator should have a minimum of elevation changes A maximum hose height of 10 feet from the floor is usually sufficient The hose should not be more than two feet above the top of the metering regulator to ensure even flow A 90 degree fitting should be used at the top of the Regulator Hose end c...

Page 6: ...metering regulator top vent The top vent elbow is necessary for venting Metering Regulator Flow Rate The abrasive flow rate coming from the Metering Regulator can be adjusted by turning the Metering Control Knob Turning the knob will change the size of the hole in the metering aperture This abrasive flow rate can be adjusted during cutting This adjustment knob is marked in one quarter graduations ...

Page 7: ... abrasive it should be discarded Verify that the air pressure regulator bowl on the pot is emptied of water Moisture or Water When the nozzle is plugged water will go up the feed hose to the regulator and discharge from the vent hole on the back of the Output Adapter If this occurs the Adapter will need to be cleared With the jet ON and the Regulator OFF plug the back VENT hole right This should v...

Page 8: ...ormally require maintenance In the event that this area does require disassembly the orientation of the parts during reassembly must be correct On the assembly drawing cut out right note the location and thickness of Sandwich plate and the Exit plate The 0 50 dimensions and plate thickness will determine the orientation and placement of both parts ...

Page 9: ...AccuStream Cutting Systems 7 13096 Abrasive Regulator II Manual 3 Drawings and Parts Lists 11484 ...

Page 10: ...AccuStream Cutting Systems 8 13096 Abrasive Regulator II Manual 4 Drawings and Parts Lists 13762 ...

Reviews: