background image

XID and XIB

•  Centrifugal backward-inclined belt or direct drive fans 
•  Performance range: 30 to 27,000 cfm (51-45,873 m3/hr)
•  Static pressure: Up to 4.0 in. wg (993 Pa)
•  Maximum operating temperature: 180°F (82°C)

XQEI

•  Performance range: 500 to 116,000 cfm (850 to 197,000 m3/hr)
•  Static pressure: Up to 5 in. wg (1245 Pa) Class I
•  Up to 8 in. wg (1990 Pa) Class II
•  Maximum operating temperature: 200°F (93°C)
•  Units are available for mounting in horizontal or vertical for installations
•  Motor positions can be rotated in the field. Fans are available in 17 sizes, 9 through 60 inches

INLINE FANS

MODEL COMPARISON

XIB AND XID MODEL OVERVIEW

Designed for clean air applications (intake, 

exhaust, return, or make-up air systems), 

where space is a prime consideration.

XQEI MODEL OVERVIEW

Uses a mixed flow wheel for quiet 

operation with high efficiencies in low to 

medium pressure ducted systems.

MODEL NUMBER CODE:

 

The Model Number Code is designed to completely identify the fan. The 

correct code letters must be specified to designate belt or direct drive and to inline fans. The remainder of the model number  
is determined by the size and performance.

MODEL

XIB

 - Inline Belt Drive

XID

 - Inline Direct Drive

MODEL

XQEI

 - Inline Fan with

Mixed Flow Wheel

FAN SIZE

60

 through

 420

FAN SIZE

09 

through

 60

PRESSURE LEVEL

HP

 - High-Pressure Wheel

CONSTRUCTION

- Class I

II 

- Class II

VG = VARI-GREEN® (DIRECT DRIVE ONLY)

MOTOR HP (BELT DRIVE ONLY)

6

 = 1/6 

 

7

 = 3/4  

30

 = 3

4

 = 1/4  

10

 = 1

  

50

 = 5

3

 = 1/3 

 

15

 = 11/2

   75

 = 71/2

5

 = 1/2  

20

 = 2  

100

 = 10

CERTIFICATIONS

NONE
X

 - UL/cUL 705 Listed (Electrical Exhaust)

G

 - UL/cUL 762 Listed (Grease Exhaust)

MOTOR RPM (DIRECT DRIVE ONLY)

A

 = 1725 

D

 = 1550

B

 = 1140  

E

 = 1050

C

 = 860  

G

 = 1300

MOTOR HP

4

 = 1/4  

15

 = 11/2  

100

 = 10 

250

 = 25 

1000

 = 100

3

 = 1/3  

20

 = 2  

200

 = 20 

300

 = 30 

1250

 = 125

5

 = 1/2 

30

 = 3 

250

 = 25 

500

 = 50 

7

 = 3/4  

50

 = 5 

300

 = 30 

600

 = 60

10

 = 1  

75

 = 71/2  

400

 = 40 

750

 = 75

XIB  –  120  HP  –  VG/5/A

XQEI  –  15  –  I  – 20  X

Summary of Contents for XRUD

Page 1: ...EXHAUST AND TRANSFER FANS 1 Engineering Simplicity into Kitchen Ventilation Systems Exhaust and Transfer Fans...

Page 2: ...a Greenheck Group company the world s leading manufacturer of commercial air movement control and conditioning equipment You can rest easy knowing you re sourcing from one trusted provider Just call o...

Page 3: ...26 XIB Indoor Mounted Non Grease Transfer Fan Belt 27 000 4 in wg 13 26 XQEI Indoor or Outdoor Mounted Inline Exhaust Fan Belt 116 000 8 in wg 13 26 XTIF Indoor or Outdoor Mounted Inline Exhaust Fan B...

Page 4: ...Roof Upblast and Sidewall Exhaust...

Page 5: ...ndards NOA and FLPA Certified MODEL NUMBER CODE The Model Number Code is designed to completely identify the fan The correct code letters must be specified to designate belt or direct drive and roof o...

Page 6: ...ssure Maximum continuous operating temperature is 400 F 204 C Seismic certified to size 200 NOA and FLPA certified to size 200 XRUBS Belt Drive Model XRUBS is used for heavy grease exhaust application...

Page 7: ...h Wind Hurricane Zone Certification Miami Dade NOA for high wind and hurricane zones 1 9 10 11 12 13 14 15 2 3 4 5 6 7 8 15 1 7 7 8 10 2 5 3 11 6 12 13 14 Wheel Backward inclined non overloading centr...

Page 8: ...ly Dual belts pulleys and keys are oversized 150 of driven horsepower Machined cast steel pulleys are adjustable for final system balancing Belts are static free and oil resistant Motor Cover Steel co...

Page 9: ...orbent material to collect grease residue for easy disposal WINDBAND EXTENSION Aluminum tube raises fan s discharge an additional 12 54 depending on fan size for special code requirements NON STICK WH...

Page 10: ...ent outside air from entering back into the building when fan is off Includes backdraft and motorized dampers Not available with UL cUL 762 GREENHECK VARI GREEN CONTROLS Remote mounted dial two speed...

Page 11: ...rstreams in commercial kitchen ventilation system designers must be aware of governing codes and guidelines The National Fire Protection Association NFPA is the primary source upon which many codes fo...

Page 12: ...th Absorbent Material Optional Optional Optional Non Stick Wheel Optional Optional Standard Windband Extension Optional Optional Optional Optional Coatings Optional Optional Standard Clean Out Port Op...

Page 13: ...INLINE FANS 1 3 Filtration Options Inline Fans...

Page 14: ...ciencies in low to medium pressure ducted systems MODEL NUMBER CODE The Model Number Code is designed to completely identify the fan The correct code letters must be specified to designate belt or dir...

Page 15: ...EL OF CONSTRUCTION 1 or 2 FAN SIZE 09 through 36 MOTOR HP 4 1 4 15 11 2 100 10 3 1 3 20 2 150 15 5 1 2 30 3 200 20 7 3 4 50 5 10 1 75 71 2 XTIF 1 24 30 XTIF Inline centrifugal fans Performance range 3...

Page 16: ...und levels Often used in commercial and industrial applications such as libraries theaters garages involving everything from clean air to grease exhaust to high temperatures XTIF Inline Fan Model XTIF...

Page 17: ...nance Bearings 100 factory tested and designed specifically for air handling applications with a minimum L10 life in excess of 100 000 hours L 50 average life of 500 000 hours Drive Assembly Drives ar...

Page 18: ...lications that involve flammable particles fumes or vapors Spark resistant construction options adhere to guidelines defined with AMCA Standard 99 0401 10 Spark B Sizes 9 33 The fan wheel is construct...

Page 19: ...an components By removing one access panel service to the wheel shaft and bearing assembly is possible without removing duct connections In addition all internal fan components can be removed from the...

Page 20: ...during operation XTIF only Inline grease exhaust fans should be installed near the end of the duct run to reduce sound at the hood Inline fan must be securely bolted to the exhaust duct per NFPA 96 g...

Page 21: ...s Electronic commutation uses electronic circuitry to control the motor s functions Solid state circuitry controls the output of power and the speed of rotation Internal circuitry converts 115 volt si...

Page 22: ...will give you 108 of cataloged performance and the left side will give you 109 of cataloged performance Refer to Fig 3 to locate an orientation that fits your application and Fig 4 and 5 for proper s...

Page 23: ...611 16 32 277 8 18 347 11 2 16x 25 3 20x 25 4 240 240HP 687 8 39 347 8 18 478 11 2 16x 25 4 300 300HP 721 8 46 417 8 16 642 11 2 20x 25 8 16x 25 10 360 360HP 791 4 52 477 8 16 871 11 2 20x 25 5 16x 25...

Page 24: ...s are designed to permit mounting the fan with the motor located on the top bottom or side hanging rods supplied by others The base isolator support brackets are designed to permit mounting of the fan...

Page 25: ...nting rails are required for this installation Fig 5 Vertical Mount All XQEI and XTIF fans can be mounted vertically ceiling hung or base mounted for either upward or downward airflow Optional mountin...

Page 26: ...ional Optional Optional Optional Mounting Rails Standard Standard Optional Optional Inlet Vane Dampers Optional Optional Aluminum Construction Optional Optional Optional Speed Controllers Optional Gra...

Page 27: ...Filtration Options Utility Fans UTILITY FANS 2 7...

Page 28: ...truction are appropriate for the requirements of this application Commercial and Institutional WAREHOUSE HOTELS ATRIUMS THEATERS GYMS LIBRARIES Larger volumes of air to 20 000 cfm with low to moderate...

Page 29: ...nd static pressures to 21 in wg 5230 Pa MODEL COMPARISON XUEF OPTIONAL DISCHARGE POSITIONS F I H J CW TH CCW TH F I H J C E A H B CW TAD CCW TAD C E A H B G F H I CW DB CCW DB G F H I D C A H E CW BAD...

Page 30: ...ons at a value It offers the flexibility of bolted or welded construction and an increased performance range for Class I airflow and pressures 200 up to 53 000 cfm Up to 5 5 in wg Spark B or C resista...

Page 31: ...and explosion proof enclosures are available Weatherhood and Motor Cover Vented steel weatherhoods and a motor cover protect the drive components from rain moisture dust and dirt Weatherhoods meet OSH...

Page 32: ...functionality as an EC motor 3 phase induction motors are just as or more efficient than single phase EC motors VFD allows motor to speed up or slow down to achieve desired RPM GREENHECK VARI GREEN M...

Page 33: ...Fans are available with a wide selection of protective and decorative coatings Grease Trap with Drain Connection Trap is designed to collect grease residue and avoid drainage onto the roof surface Dis...

Page 34: ...nsist of laterally stable free standing springs assembled into a steel housing These assemblies are designed for vertical and horizontal motion restraint Restrained spring isolators can be used for bl...

Page 35: ...line and the exhaust duct must be fully welded to a distance of 18 inches 457 mm above the roof surface No dampers are to be used in the system 18 in 457 mm Duct from Kitchen Hood Weatherhood Per NFPA...

Page 36: ...ptional Equipment Supports Optional Optional Optional Extended Lube Lines Standard Optional Optional Inlet and Outlet Guards Optional Optional Optional Coatings Optional Standard Grease Trap with Drai...

Page 37: ...UTILITY FANS 3 7...

Page 38: ...Roof Exhaust...

Page 39: ...Certified MODEL NUMBER CODE The Model Number Code is designed to completely identify the fan The correct code letters must be specified to designate belt or direct drive The remainder of the model nu...

Page 40: ...emperature of 180 F 82 C Seismic certification to size 200 High wind certification to size 200 XREB Belt Drive Model XREB belt drive centrifugal fans are specifically designed for general clean air ro...

Page 41: ...between the fan shroud and the motor cover directly into the motor compartment Positive motor cooling with fresh air results in maximum motor life Vibration Isolation True vibration isolators contain...

Page 42: ...e for indoor and outdoor environments Hi Pro Polyester Available in 7 standard decorative colors Hi Pro Polyester is resistant to saltwater chemical fumes and moisture in more corrosive atmospheres Ty...

Page 43: ...ger motor life and reduces energy consumption see Motor Turndown Comparison chart at right 80 usable turndown vs 30 The VG motor provides an easier solution for variable volume systems and system bala...

Page 44: ...amount of conditioned air that is exhausted further reducing the total operating costs For more detailed information refer to the Greenheck Vari Green Motor brochure on accurex com A 0 10 VDC control...

Page 45: ...hes 305 mm fully welded straight sides with a 5 inch flashing flange GPF is available up to 24 inches 460 mm in height to meet greater height requirements Model GPFHL for heavy load applications Its c...

Page 46: ...curbs should be 11 2 inches 3 4 inch on a side less than the unit curb cap to allow for roofing and flashing Installation must include a means for inspecting cleaning and servicing the exhaust fan Da...

Page 47: ...CEILING AND CABINET FANS 4 7 Filtration Options Ceiling and Cabinet Fans...

Page 48: ...ode is designed to completely identify the fan The correct code letters must be specified to designate belt or direct drive and roof or wall mounted configurations The remainder of the model number is...

Page 49: ...bathtub shower with GFCI branch protected circuit XCR C The XCR C is our economy ceiling fan designed for light commercial applications Sound levels as low as 3 sones Profile as low as 35 8 inches 7 6...

Page 50: ...tachment screws securely fasten grille to housing for quiet and rattle free operation Mounting Brackets Fully adjustable for multiple installation conditions Housing Embossed galvanized steel for rigi...

Page 51: ...ncealed attachment screws securely fasten grille to housing for quiet and rattle free operation Mounting Brackets Fully adjustable for multiple installation types Housing Embossed galvanized steel for...

Page 52: ...and safe Decorative Grille Quickly snaps into place 1 2 3 4 5 Mounting Brackets Adjustable for several installation types Housing Galvanized steel for rigidity and low profile for height restricted a...

Page 53: ...ing Access Panel Gain easy access to internal components once installed Mounting Brackets Fully adjustable for multiple installation conditions Housing Embossed galvanized steel for rigidity Motor All...

Page 54: ...on types 1 2 3 4 5 6 7 Housing Embossed galvanized steel for rigidity and low profile for height restricted areas Motor All motors are compatible for use with speed controls and have thermal overload...

Page 55: ...ound Duct Adapter Optional Sizes A110 through A510 Vertical Discharge Exhaust outlet duct may be installed in the optional vertical position The power assembly must be rotated to match the duct adapte...

Page 56: ...15 amp UL Listed Requires 4x4 handy box SWITCHES Switches may be used on models XCR and XIR fans to enable manual control of your fan or fan light combination There are several options to fit your ap...

Page 57: ...same manner as a standard switch however there is a delay of 10 20 30 and 60 minutes after the switch has been turned off Single switch controls both fan and light Available shipped loose Silent oper...

Page 58: ...or and wheel filters also reduce sound levels CEILING RADIATION DAMPERS The Accurex XCR A and XCR B ceiling radiation dampers are UL Classified rated at three hours fire resistance and are available o...

Page 59: ...al Optional Optional Optional Transformers Model T 2 0 Optional Optional Optional Optional Optional Model T 4 3 Optional Optional Optional Optional Optional Model T 6 5 Optional Optional Optional Opti...

Page 60: ...Roof Curbs...

Page 61: ...de is designed to completely identify the roof curb The correct code letters must be specified to designate configurations and size MODEL OVERVIEW Square Curbs Rectangular Curbs GPI R 34 24 G 12 GPI R...

Page 62: ...se with Accurex s model XRUB XRUBS or XRUD fan to provide the required 40 inch minimum discharge height above the roofline per NFPA 96 ROOF CURBS MODEL COMPARISON OPTIONS AND ACCESSORIES Damper trays...

Page 63: ...GESI has heights ranging from 8 to 18 inches and widths of 4 6 or 8 inches are available Model VCE The VCE vented curb extension is typically used in kitchen applications where the vents allow hot ai...

Page 64: ...Discover how simple the Accurex way can be at Accurex com P O BOX 410 SCHOFIELD WI 54476 PHONE 800 333 1400 FAX 715 241 6191 ACCUREX COM 2021 Accurex LLC 01 ACX 1004 R5 12 2021...

Reviews: