ACCURATE ELECTRONICS 104001C Manual Download Page 9

 

ACCURATE ELECTRONICS INC

                               

Practice Section 104001C  Rev B    January 2014

 

 

WWW.ACCURATE.ORG

    PO BOX 1654  97075-1654    8687  SW HALL BLVD  97008      BEAVERTON OR  USA    503.641.0118     FAX 503.646.3903 

 

This document contains proprietary information and is supplied for identification, maintenance, engineering evaluation or inspection purposes only and shall not be duplicated or disclosed without written 
permission of:  ACCURATE ELECTRONICS INC By accepting this document the recipient agrees to make every effort to prevent unauthorized use of this information. 

 

 

 

FIGURE 1.

 CIRCUIT DESCRIPTION. 

TABLE 5

.  Test Guide Checklist. 

TEST 

TEST PROCEDURE 

NORMAL RESULTS 

IF NORMAL CONDITIONS ARE NOT 
MET, VERIFY: 

Receive Level 

Arrange transmit portion of transmission measuring set 
(TMS) for 1004Hz tone output at  –20dBm if module’s 
RCV channel is optioned for gain or at 0dBm if 
module’s RCV channel is optioned for loss.  Also set 
transmit portion of TMS for facility-side interface 
impedance selected on module.  Connect 1004Hz signal 
to RCV in jack.  Arrange receive portion of TMS for 
terminated measurement at terminal-side inter-face 
impedance selected on module, and connect it to RCV 
out jack. 

Signal level indicated on TMS 
corresponds to receive gain or 
loss setting on module. 

- Power  

- Wiring 

- Proper impedance termination 

(check for double termination) 

- Impedance switches (S1 and S3) properly set 

- Level switches (RCV gain/loss and RCV level) 
properly set 

- Replace module and re-test 

Receive 
Equalization 

Maintain connections as above.  Adjust RCV EQL 
switches for no equalization (all switches set to out).  
Adjust module’s receive output level for 0dBm at 
1004hz.  Change input frequency to 2804Hz and add 
equalization (up to maximum) by setting RCV EQL 
switches to in one by one. 

Receive output level at 2804 Hz 
increases to +7.5 dBm as 
equalization is added. 

- Input level at 2804Hz same as at 1004Hz 

- Terminating impedance correct 

Transmit Level 

Arrange transmit portion of TMS for 1004Hz tone 
output at –20 dBm if module’s XMT channel is optioned 
for gain or at 0dBm if module’s XMT channel is 
optioned for loss.  Also set transmit portion of TMS for 
terminal-side interface impedance selected on module.  
Connect 1004Hz signal to XMT in jack.  Arrange 
receive portion of TMS for terminating measurement at 
facility-side interface impedance selected on module, 
and connected it to XMT out jack. 

Signal level indicated on TMS 
corresponds to transmit gain or 
loss setting on module. 

- Power 

- Wiring 

- Proper impedance terminations (check for double 
terminations) 

- Impedance switches (S1 and S3) properly set. 

- Level switches (XMT gain/loss and XMT level) 
properly set 

- Replace module and re-test 

Transmit 
Equalization 

Maintain connection as above.  Adjust XMT EQL 
switches for no equalization (all switches set to out.  
Adjust module’s transmit output level for 0dBm at 
1004Hz.  Change input frequency to 2804Hz and add 
equalization (up to maximum) by setting XMT EQL 
switches to in one by one. 

Transmit output level at 2804 
Hz increases to +7.5 dBm as 
equalization is added. 

- Input level at 2804Hz same as at 1004Hz 

- Terminating Impedance correct 

 

FIGURE 1.  

CIRCUIT DESCRIPTION.

 

Summary of Contents for 104001C

Page 1: ...to the transmit input receive output side as shown in Figure 1 of this practice 1 03 This practice section is reissued to cover the Issue 4 version of the 104001C module Accurate Electronic part numb...

Page 2: ...mounted across a 23 inch rack The 104001C can also be used in the Accurate 246 Resistive Data Bridge System in which case the module mounts in one position of the Accurate 246 Mounting Assembly The 2...

Page 3: ...n both the facility and terminal sides the 104001C can interface a variety of facilities and equipment as listed in Table 2 The 150 ohm options provide a small amount of slope equalization for long se...

Page 4: ...lf position Pin numbers are found on the body of the connector TABLE 3 External Connections to 104001C CONNECT To PIN XMT OUT TIP 41 XMT OUT RING 47 XMT OUT SIMPLEX 43 and 45 RCV IN TIP 7 RCV IN RING...

Page 5: ...rement is expressed as EMG both the transmit and receive portions of the transmission measuring set TMS used for alignment must be optioned for 600 ohms Receive Channel 1 Determine from the CLR whethe...

Page 6: ...terminated measurement at the terminal side interface impedance selected on the module Connect the receive portion of the TMS to the module s RCV OUT jack The transmit portion of the TMS must remain d...

Page 7: ...slope type amplitude equalizer consisting of the EQUALIZATION ADJUST circuit and EQL AMP The EQUALIZATION ADJUST circuit is controlled by the channel s front panel EQL switches These switches allow se...

Page 8: ...ate for repair or replacement as directed below We strongly recommend that no internal component level testing or repairs be attempted on the module Unauthorized testing or repairs may void the module...

Page 9: ...ve Equalization Maintain connections as above Adjust RCV EQL switches for no equalization all switches set to out Adjust module s receive output level for 0dBm at 1004hz Change input frequency to 2804...

Page 10: ...document contains proprietary information and is supplied for identification maintenance engineering evaluation or inspection purposes only and shall not be duplicated or disclosed without written pe...

Reviews: