Warning 

The following warnings must be exactingly observed: 

 

Failure  to  comply  with  the  warnings  may  result  in  fire,  property 
damage, electric shock, injury or death. 

 

To prevent suffocation, electric shock, injury or death, the customer 
is responsible to ensure that children shall NOT access the product. 

 

The product shall not be modified, disassembled or serviced. 

 

The  product  shall  be  shut  down  if  the  outdoor  air  temperature 
exceeds 35ºC or 95ºF. 

 

The vents (A and C) of the product shall NOT be blocked at all. 

 

The enclosure shall not be opened when the product is powered. 

 

The electrical parts of the product shall not be touched even if the product 
has  been  shut  down.  The  electrical  parts  are  the  fans  (

F

  and 

G

),           

power bar (

I

), and supply fan controller (

J

). 

 

As  soon  as  possible,  the  power  supply  cord  (

E

)  shall  be  safely 

disconnected from the electrical mains if there is a spillage of liquid on or 
around the product. 

 

The power bar (

I

) shall only be connected to an electrical receptacle that is 

permanently installed in a building. 

 

The power bar (

I

) shall not be connected to a relocatable power tap. 

 

There shall be no connection of any external devices to the power bar (

I

). 

 

The  cables  of  the  fans  (

F

  and 

G

)  shall  not  be  disconnected  from  the  

power bar (

I

). 

 

The supply fan controller (

J

) shall not be adjusted in order not to disrupt 

the calibration of the product. 

 

NOTE 

 

The manufacturer 
supplies third-party 
locks that the customer 
may install to shut the 
door of the enclosure.

 

NOTE 

 

A strip of paper tape is 
attached to the supply 
fan controller (

J

) on a 

parallel axis to the 
calibrated position of 
the controller knob.

 

 

 

Installation 

The following points shall be strictly observed when installing the product: 

 

The product shall not be installed near hazardous or toxic materials. 

 

The  product  shall  only  be  installed  in  either  vertical  or  horizontal 
orientations and shall not be positioned at an oblique angle. 

 

For  vertical  orientation,  the  supply  vent  (A)  shall  face  upwards  as 
indicated  in  Figure  1(a).  There  is  no  restriction  on  the  horizontal 
orientation  of  the  product  provided  the  exhaust  vent  (C),  exhaust 
duct (D), and power supply cord (E) are not obstructed. 

 

The  product  can  be  placed  on  the  floor  or  a  sturdy  table. 
Professional help may be needed to install the product on a wall. 

 

The vents (A and C) and ducts (B and D) shall NOT be connected 
to external appliances such as dryers, fans, furnaces, etc. 

 

The product shall be installed in the conditioned space of a building where 
the  temperature  and  relative  humidity  of  air  are  within  the  range  of          
22ºC – 24ºC and 35% – 50%, respectively. 

 

The product shall not be powered until the ducts (

B

 and 

D

) are installed. 

 

A ventilation kit (not bundled with the product) is needed to install the two 
ducts (

B

 and 

D

) such that air can securely and simultaneously be supplied 

to and expelled from the building space. 

 

The ventilation kit can interface with the outdoors though a window, door 
or wall as illustrated in 

Figure 3

. If the product is vented through a wall, 

the customer is responsible for complying with all applicable codes. 

 

To power the product, connect the plug of the power supply cord (

E

) to 

the  electrical  mains  (~120V  AC,  ~60Hz).  To  shut  down  the  product, 
disconnect the power supply cord (

E

) from the electrical mains. 

 

NOTE 

 

The product shall not be 
installed at a location 
where there is probable 
contact with liquids.

 

NOTE 

 

The product shall be 
carefully positioned 
such that it may not trip 
and cause property 
damage or bodily injury.

 

NOTE 

 

The product shall not be 
installed at a location 
where there is excessive 
heat or exposure to 
direct sunlight.

 

NOTE 

 

The ports of the 
ventilation kit shall be   
4” (~10.2 cm).

 

NOTE 

 

The product is 
calibrated to an air flow 
rate of ~10 CFM.

 

NOTE 

 

The power consumed 
by the product is 
nominally 30W.

 