AccuMed AP212 User Manual Download Page 9

 

 

BATTERY: 
 
Battery information 

Capacity: 110mAh Voltage: DC 3.7V Restriction: 4.2V 
 
Charging the Battery 

1) The Lithium battery can be recharged through both the AC adaptor and a computer USB input. 
2) Turn off the unit. 
3) Connect the unit and the charger with the USB cable. Plug charger into any power outlet and a red light will show when it is 

charging. The charging process will take approximately 1 hour. When charging is finished, the LCD will show a full battery cell. 

4) The battery should be charged for 10 hours or so before the first use. 

 
NOTE: 

Only charge the unit when battery is completely drained the first 2 times. Unplug the charger from power outlet when 

charging is complete. When stimulation intensity decreases, it indicates that the device needs charging. Recharge it and then 
continue to use the device. Do not use the device while charging.

 

 

CLEANING AND MAINTENANCE: 

 
A. 

FOR THE CONTROL UNIT: 

1. 

To keep the controller clean, use a soft, dry cloth for dust or a soft damp cloth for any dirt and smudges. Do not use any 
cleaning solutions to clean the controller and its pads. 

2. 

Do not use or store the device where there are magnetic fields or electric waves (near TV set or speakers). 

3. 

Do not place the devices in areas of high temperature, high humidity, or under direct sunlight. 

4. 

Keep the device out of reach of children. 

5. 

All worn accessories should be disposed of according to your local regulations. 

 

B. 

FOR ELECTRODE PADS: 

1. 

Unplug the output cord from the output jack of the controller after each use. Cover both pads with the protective film before 
storing. Never fold the electrode pads. 

2. 

Between uses, store the electrodes in the reusable bag in a shady place. Stock room temperature: +5°C~+27°C (41-80°F) and 
humidity of 30%~80%. No need to sterilize. 

3. 

Never apply the pads to any other surface other than your skin. If the pads become soiled or dirty, the adhesiveness may 
decrease. In this case, moisten the surface of the pads with water and wipe away the dirty portion. This will allow a temporary 
restoration of the adhesiveness. However, too much water will result in loss of the adhesiveness. 

4. 

The life of the electrodes varies depending on skin conditions, storage, amount of use, type of stimulation, and stimulation site. 
Electrode life may be extended by carefully following this Instruction for Use. The expired electrodes are to be recycled to not 
harm environment. 

 
WARNING

: The electrodes are intended for single patient use only! 

 

STORAGE: 

CAUTION: Do not store in a damp area. Dampness may affect the device and cause rust. 

 

Normal working ambient temperature: 5°C~40°C (40-104°F) 

 

Normal working ambient humidity: ≤80%RH 

 

Store and transport ambient temperature: -20°C~55°C (4° -131° F) 

 

Store and transport ambient humidity: ≤93%RH 

 
HOW TO STORE DEVICE: 

1. 

If you need to turn off the device during stimul

ation, slide the On/Off switch to “OFF”.  

2. 

Before storing the TENS use the protective film to cover the electrode pads. 

3. 

Put away the connecting wires and electrode pads. 

 
 
 
 
 
 
 

Summary of Contents for AP212

Page 1: ...USER MANUAL AccuMed AP212 Mini Electronic Pulse Stimulator AP212 USER MANUAL V2 0 1 Revised March 10 2017 www AccuMed com ...

Page 2: ... OF CONTENTS INTRODUCTION 3 SAFETY WARNINGS 3 SPECIFICATIONS AND ESSENTIAL PERFORMANCE 4 FEATURES 5 INTENDED USE 5 DEVICE OVERVIEW 5 TWO KEY POINTS FOR OPERATIONS 6 RECOMMENDED PRACTICES 7 READJUSTMENTS ALTERATIONS AND REPAIRS 8 CLEANING AND MAINTENANCE 9 TROUBLESHOOTING 10 RECOMMENDED PLACEMENT AREAS 11 ...

Page 3: ...r abnormal blood pressure lack of skin sensation or an abnormal skin condition any condition requiring the active supervision of a physician Do not use this device while driving Do not use this device while sleeping Do not use this device in high humidity areas such as a bathroom Keep the device away from moisture high temperatures and direct sunlight Keep this device out of reach of children Stop...

Page 4: ...ouch the USB port when using the device The USB port is only used to connect the charger Do not connect other devices 3 The charger supplied by the manufacturer must in compliance with IEC EN 60601 1 the use of unauthorized chargers can impair the safety or damage the device 4 The battery needs to be charged for up to 10 hours before the first use 5 Only charge the unit when battery is completely ...

Page 5: ...in the shoulders waist neck back arms and legs due to strain from exercise or normal household and work activities DEVICE OVERVIEW Self adhesive electrodes 510 k cleared Battery charger 800mm 30 5 long USB cable 1500mm 59 long Electrode cable INCLUDED IN THIS PACKAGE 1 Controller 2 Pairs of electrodes 510 k cleared 2 Output electrode cables 1 USB cable 1 Charger 1 User s manual 1 Plastic holder ...

Page 6: ...lashes on the screen which indicates the channel you are in 2 Press the button to increase the intensity 3 Press the button to decrease the intensity CHANGE MODES 1 The device will automatically enter Mode 1 Variation I when turned on Press the Play Pause button to access the next variation in the main illustrated mode 2 Press the Play Pause button to access the next variation within the same mode...

Page 7: ...ensitive areas or people with sensitivity to pulse sensations like pulling on your ear lobe NOTE Start from the lowest intensity and then gradually adjust to a comfortable level on a scale from 1 to 10 RECOMMENDED PRACTICES 1 Start by using it 1 2 times per day for each treatment area for 10 to 20 minutes 2 Be sure the treatment site is clean of dirt body oil and other cosmetics 3 The lifespan of ...

Page 8: ...ou feel unusual discomfort stop using the device immediately Many people experience immediate relief from muscle pain while others require several days of regular use to feel the benefits The results vary and will depend upon your underlying conditions and how often you use the device If your pain does not improve you can try to increase the intensity and time or change the mode ELECTRODE PADS GUI...

Page 9: ...ing to your local regulations B FOR ELECTRODE PADS 1 Unplug the output cord from the output jack of the controller after each use Cover both pads with the protective film before storing Never fold the electrode pads 2 Between uses store the electrodes in the reusable bag in a shady place Stock room temperature 5 C 27 C 41 80 F and humidity of 30 80 No need to sterilize 3 Never apply the pads to an...

Page 10: ...de pads lost their adhesiveness and need to be replaced Wash adhesive surface of pads softly with your fingertips for about 3 seconds under slow running water Make sure you are not perspiring and are in a cool room when using If electrode pads were applied immediately after washing make sure to dry the pad before applying If the electrode pads were exposed to high temperature high humidity or dire...

Page 11: ...ders Keep the area warm Avoid sudden movements with the aching shoulders Gentle movements are advisable in the initial stage and full motions at a later stage Pain in Back Mode 1 for 10 20 minutes and Mode 5 or 6 for 10 20 minutes twice or 3 times a day Apply the electrodes to the pain area Avoid working in the same position in the initial phase and change the position at times Pain in Waist Figur...

Page 12: ...20 minutes Mode 6 for 10 20 minutes and Mode 3 for 10 20 minutes twice or 3 times a day The device can stimulate areas of the legs and thighs so as to improve the muscles Abdomen Mode 1 for 10 20 minutes Mode 2 for 10 20 minutes and Mode 6 for 10 20 minutes twice or 3 times a day Persistent and consistent use can help to improve the abdomen muscles Waist Mode 2 for 10 20 minutes Mode 3 for 10 20 m...

Page 13: ...E The images below are mere suggestions on where to place the electrodes but only after the user has gone through the starting procedure this entire user manual and is familiar with the device Targeted muscle ...

Page 14: ...14 ...

Page 15: ...ase visit www AccuMed com Manufactured for AccuMed Biotech 16727 Park Row Drive Houston TX 77084 713 904 1955 Model AP212 Input DC 3 7V Weight 110g Size 83 42 9mm AP212 Use Only apply stimulation to normal intact clean skin Storage 20 55 C 93 humidity 50 106KPa Refer to User Manual before using Distributed by Amcrest Technologies LLC Notes Symbol Meaning Class II equipment Type BF applied part Ope...

Reviews: