Before you start ---- Warnings & Cautions

 

 

 

 

 

Warnings: 

Follow these guidelines to avoid personal injury:

 

1.

 

Only use this instrument in the manufacture specified 
temperature range. 

2.

 

The handle of this instrument can become hot when it is used 
to measure high temperatures for extended periods of time. 

3.

 

DO NOT submerge SPRT handle when taking measurement. 

4.

 

DO NOT use this instrument to measure the temperature of 
any hazardous live component. 

5.

 

Follow all other safety guidelines listed in this user’s guide. 
 

 

Cautions: 

Follow these guidelines to avoid possible damage to 

the instrument:

 

1.

 

Avoid mechanical shocks. DO NOT drop or slam the probe in 
any way. This will cause damage to the probe internally and 
affect its calibration and accuracy. 

2.

 

Read Section entitled “Care and Handling Guidelines” before 
removing the SPRT from the shipping box. Incorrect handling 
can damage the SPRT and void the warranty. 

3.

 

Keep the shipping container in case it is necessary to ship the 
PRT. Incorrect packaging of the SPRT for shipment can cause 
irreparable damage. 

4.

 

Calibration equipment should only be used by trained 
personnel. 

 

 

 

 

Summary of Contents for AM1950

Page 1: ...Rev 201609V3 AM1960 1950 Standard Platinum Resistance Thermometer User s Guide Please download the latest version at www accumac com...

Page 2: ...es 3 1 3 Calibrations 3 2 Specifications 4 2 1 Specifications 4 3 General Operations 5 3 1 Connecting to the readout device 5 3 2 Drive Current 5 3 3 Stability of Readings 5 3 4 Immersion Requirements...

Page 3: ...hazardous live component 5 Follow all other safety guidelines listed in this user s guide Cautions Follow these guidelines to avoid possible damage to the instrument 1 Avoid mechanical shocks DO NOT d...

Page 4: ...perature calibration labs at various levels 1 2 Main Features Extreme low drift rate Quartz sheathed Great primary or secondary reference standards 1 3 Calibrations As a temperature standard each AM19...

Page 5: ...after 10 times thermal cycles from minimum to maximum temperatures Self heating 0 0015 C at 1 mA current Measurement Current 1 mA Sensor Length 42 mm Insulation Resistance 1000 M at room temperature...

Page 6: ...ttached to each end of the sensor are identified by red black and white blue insulation 3 2 Drive Current AccuMac recommends 1mA as drive current to ensure the best measurement 3 3 Stability of Readin...

Page 7: ...ach AccuMac SPRT has gone through an annealing process and stability test to minimize the thermal EMF which is caused by either impurities of sensing element or temperature differentials at lead wires...

Page 8: ...enever possible b When shipping the SPRT use protective box and other protective packaging materials to minimize mechanical shocks as much as possible c When using dry blocks make sure the well diamet...

Page 9: ...r repair service Be sure to have the model number and serial number of your SPRT available 5 2 Problem Causes and Solutions a R0 Rtpw becomes higher significantly This is likely caused by mechanical s...

Page 10: ...The warranty period begins on the date of the shipment Parts product repairs and services are warranted for 90 days The warranty extends only to the original buyer or end user customer of an AccuMac...

Reviews: