Upper and bottom view of ACD-10203: 

 

 

Function description 

1.

 Switch button for input signal selection

: Offering switch input 

signal between VGA port and 25pin D-sub signal (AMAT machine) 

2. 

Switch button for operation mode selection

: Offering change 

between using light-pen and finger tip to operate system 
alternatively. 

3. 

LED indicator for operation mode selection

: Green LED lit to 

indicate that it is operated under light-pen mode. 

4.

 Access indicator & monitor calibration button

: The button 

with built-in LED indicator. Press and hold 3 seconds then release to 
enter to calibration mode, the built-in LED lit to indicate the monitor 
is accessed. 

5.

 Touch pen plug

: RJ-11 type, for connecting the original light-pen 

of AMT system or touch pen. 

6. 

25 pin DB type connector

: DB-25 type, for receiving the VGA 

signal from AMAT system. 

7. 

15 pin D-sub connector

: Standard VGA display port for PC. 

8. 

RS-232

: a phone jack type RS-232 for R/D debug port. 

9. 

DC Power input

: Providing DC power to ACD-10203 from adapter. 

Introduction 

1

1

 

 

Switch button for input signal 

selection 

Switch button for operation mode 

selection 

LED indicator for operation mode 

Access indicator & monitor 

calibration button 

Touch pen connector 

25 pin DB type connector (for 

AMAT machine) 

15 pin D-sub(VGA port)   

RS-232   

DC Power input 

 

 

 

 

 

Caution 

For the safety concern, 

turn off 

and disconnect all 

electrical power from the system before beginning 

installation.

 

 