background image

 
 
 
 
 

state’s health department guidelines). For more information on how to have your device re- calibrated 
or to replace a valid certificate, contact us at 

[email protected].

 

The temperature sensor, or probe, is enclosed in a glycol-filled bottle that is stored inside your unit in 
a special compartment. 
 

Function of Controls 

RESET Key:

 Press and hold to reset Max/Min temperature history.  

 

ALARM ON/OFF:

 Press for 2 seconds to turn the alarm feature ON/OFF. 

 

ºC/ºF Key:

 Press this button to change the temperature display scale from Celsius (ºC) to Fahrenheit 

(ºF). 
 

VOL/ :

 Press once to choose between a high and low alarm sound level.  

 

Programming the Alarms 

 
By default, the high alarm temperature setting is -15°C (5°F) and the low alarm temperature setting 
is -50°C (-58 °F).  
 
When the alarm is ON, the 

 icon will be displayed, and you will receive visual and audible alarm 

notifications. 
 
To program the high temperature alarm setting, press the HIGH ALARM key once to enter the high 
temperature alarm setting mode. HI-SET will display on the LCD screen. Pre

ss ▲ or ▼ to increase 

or decrease the value.  Then, press the HIGH ALARM button to confirm. The LCD screen will return 
to the current temperature. 
 
To program the low temperature alarm setting, press LOW ALARM key once to enter the low 
temperature alarm setting mode. LO-

SET will display on the LCD screen. Press ▲ or ▼ to increase 

or decrease the value.  Then press the LOW ALARM button to confirm. The LCD screen will return 
to the current temperature. 
 

NOTE:

 The TMD can be locked to avoid accidental adjustments. By default, the TMD is unlocked. 

Long press 

ºC/ºF 

and 

VOL/

 keys simultaneously for 6 seconds to lock all the alarm 

features. 

LOCK

 will display on the screen when the unit is successfully locked. When the 

TMD is locked, the alarm features and functions are inaccessible, except for silencing 
beeping sound. 

 
If the temperature rises above or falls below the set temperature range, the alarm will emit a beeping 
sound, and the HI-ALARM/LO-ALARM indicator on the display will blink until the temperature is back 
in range. 

To silence the alarm, press any button. The beeping sound lasts for 60 seconds, but the high 

and  low  indicators  will  remain  on  display  even  when  the  unit  gets  back  in  range.  Press  the  LOW 
ALARM and RESET keys simultaneously to clear the LO-ALARM/HI-ALARM display indicators. The 
alarm will beep every 30 minutes if the same alarm event exists, even if the user has silenced the 
alarm.  The alarm will NOT clear if an alarm event still exists.   

 

 
More  details  about  the  features  and  usage  of  the  TMD-02  can  be  found  in  the  User  Manual 
accompanying the unit. 
 
This appliance is equipped with a 

3/8” probe port and plug, which can accept additional monitoring 

devices. It is advisable to position the additional temperature monitoring device in the net usable area 
(inside the baskets, ideally the middle basket).   

Summary of Contents for VT65MLVAC456

Page 1: ...__ NSF 456 CERTIFIED VACCINE FREEZERS Models VT65MLVAC456 VT65MLVAC456ADA User Manual BEFORE USE PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS Accucold Division of Felix Storch In...

Page 2: ...s recommended that a separate circuit serving only your unit be provided Use receptacles that cannot be turned off by a switch or pull chain Never clean the equipment parts with flammable fluids These...

Page 3: ...n that the pipes are not pinched kinked or damaged during installation Check for leaks after connection Never allow children to operate play with or crawl inside the unit Do not use solvent based clea...

Page 4: ...Electrical Connection 7 Reversing the Door Swing 7 Door Handle Installation 7 Operating your Freezer 8 Digital Thermostat 8 Temperature Monitoring Device TMD 9 10 Storage 10 Defrosting 10 Care and Mai...

Page 5: ...Hz Rated Current 1 3A Temperature Setpoint 30 C Refrigerant R134a 2 7 oz Installation Built in or Free standing Built in or Free standing Unit Dimensions H x W x D 33 5 to 34 5 x 23 63 x 23 5 32 0 x 2...

Page 6: ...nit will be built into an enclosure you must still allow at least 1 4 of clear space on both sides and at the top and 2 at the back Take care that the air vents at the front are never covered or block...

Page 7: ...lling on the power cord Always grip the plug firmly and pull straight out from the receptacle Repair or replace immediately any power cord that has become frayed or otherwise damaged Do not use a cord...

Page 8: ...it provides a temperature readout based on the buffered probe in order to better simulate the temperature of what is actually stored inside the unit as opposed to the air temperature itself As a resul...

Page 9: ...e LCD screen Press or to increase or decrease the value Then press the LOW ALARM button to confirm The LCD screen will return to the current temperature NOTE The TMD can be locked to avoid accidental...

Page 10: ...efore defrosting the unit remove the contents of the freezer then set the thermostat to OFF the compressor will stop working Leave the door open until ice and frost are completely melted To speed up d...

Page 11: ...nger period of time you need to take the proper steps to protect your frozen items Vacation Time During long absences remove all the contents of the freezer Unplug the freezer clean it and leave the d...

Page 12: ...t has just recently been closed you may find it hard to open This is because when you open the door warm air gets into the appliance and when it is cooling lower interior pressure seals the door The d...

Page 13: ...nstallation installation not in accordance with electrical or plumbing codes or use of products not approved by warrantor 4 Replacement parts or repair labor costs for units operated outside the Unite...

Page 14: ...s les panneaux avant de faire fonctionnement l appareil Il est recommand d utiliser un circuit distinct afin d alimenter votre appareil uniquement Utilisez des prises qui ne peuvent pas tre d sactiv e...

Page 15: ...ous que les tuyaux ne soient pas pinc s nou s ou endommag s lors de l installation V rifier des fuites apr s la connexion Ne jamais laisser les enfants utiliser jouer ou ramper l int rieur de l appare...

Page 16: ...e 35 C Refrig rant R134a 2 7 oz Installation Int gr ou Sur Pied Int gr ou Sur Pied Dimensions de l unit Ha x La x Pr 33 5 to 34 5 x 23 63 x 23 5 32 0 x 23 63 x 23 5 NOTES Ces cong lateurs sont appropr...

Page 17: ...oidir le compresseur et le condenseur Si votre mod le a les lettres de BI dans son num ro de mod le l appareil peut tre install soit autoportant ou encastr Si l unit sera construite dans une enceinte...

Page 18: ...droit sorti de la prise R parer ou remplacer imm diatement tout cordon d alimentation qui est devenu us ou endommag Ne pas utiliser un cordon qui pr sente des fissures ou une usure sur sa longueur ou...

Page 19: ...ppuyez sur la fl che HAUT ou BAS pour modifier le point de consigne la temp rature souhait e Appuyez nouveau sur le bouton SET pour quitter le r glage L affichage revient la temp rature de l air inter...

Page 20: ...Appuyez pendant 2 secondes pour activer d sactiver la fonction d alarme Touche C F Appuyez sur ce bouton pour modifier l chelle d affichage de la temp rature de Celsius C Fahrenheit F VOL Appuyez une...

Page 21: ...id alement le panier du milieu Stockage des articles Rangez les vaccins et autres articles congel s dans l un des trois tiroirs sous la ligne de chargement REMARQUE Assurez vous de ranger tous les art...

Page 22: ...e vous devez prendre les mesures appropri es pour prot ger vos produits congel s Vacances Pendant de longues absences supprimer tous les contenus du cong lateur D branchez le cong lateur le nettoyer e...

Page 23: ...lateur vous pouvez rencontrer certains probl mes qui dans de nombreux cas peuvent r sulter d une mauvaise manipulation de l appareil et peuvent tre facilement limin s L appareil ne fonctionne pas apr...

Page 24: ...l appareil et quand il se refroidit la pression int rieure plus basse scelle la porte La porte peut tre ouverte plus facilement en appuyant l g rement le joint contre la porte et en tirant sur la port...

Page 25: ...ise installation une installation non conforme aux codes d lectricit ou de plomberie ou l utilisation de produits non approuv s par le garant 4 Les pi ces de rechange ou les frais de r paration pour l...

Reviews: