APPLIANCE SAFETY 

Your safety and the safety of others is very important. 

We have provided many important safety messages in this manual. Always read and follow all safety 
messages. Serious injury or even death can result from not following these instructions. All safety 
messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell 
you what can happen if the instructions are not followed.  
 
 
• 

Keep the cooler upright while it is turned on and in use. 

• 

Never switch the cooler on with wet hands or when your feet are in contact with water. 

• 

If connected to a DC power source (for example, a data port socket) in a vehicle, do not attempt to 
turn the cooler on when your vehicle engine is not turned on. 

• 

Always be sure the correct voltage and current are applied to the cooler. The voltage and current are 
clearly marked on the manufacturer's label, which can be found on the side of the cooler. 

• 

Be sure the power source can safely supply the required current when you use the AC/DC adapter. 

• 

Do not carry corrosives or solvent material in the cooler. 

• 

Never obstruct vents as they supply necessary airflow to motors and fans. 

• 

Do not fill cooler with liquid or ice. 

• 

Disconnect the power before servicing or cleaning. 

• 

Use nonflammable cleaners. 

• 

Keep flammable materials and vapors, such as gasoline, away from the cooler. 

• 

Do not attempt to repair or replace any part of your appliance unless it is specifically recommended in 
this manual. All other servicing should be referred to a qualified technician.   
 
 
 

• 

The SPFZ25 is CFC- and HFC-free and contains a small quantity of propane (R290) which is 
environmentally friendly, but flammable. It does not damage the ozone layer, nor does it increase the 
greenhouse effect.  

• 

Care must be taken during transportation and setting up of the appliance that no parts of the cooling 
system are damaged. Leaking coolant can ignite and may damage the eyes.  

• 

In the event of any damage:  

o

 

Avoid open flames and anything that creates a spark, 

o

 

Disconnect from the electrical power line, 

o

 

Air the room in which the appliance is located for several minutes and  

o

 

Contact the Service Department for advice. 

• 

The more coolant there is in an appliance, the larger the room it should be installed in. In the event of 
a leakage, if the appliance is in a small room, there is the danger of combustible gases building up. 
The amount of coolant in the appliance is stated on the data plate on the appliance. It is hazardous 
for anyone other than an Authorized Service Person to carry out servicing or repairs to this appliance.  

• 

Take serious care when handling, moving, and using the appliance to avoid either damaging the 
refrigerant tubing or increasing the risk of a leak. 

• 

Replacing component parts and servicing shall be done by factory authorized service personnel so as 
to minimize the risk of possible ignition due to incorrect parts or improper service. 
 

 
 
 
 
 
 
 
 

Summary of Contents for SPFZ25

Page 1: ...PORTABLE REFRIGERATOR FREEZER Models SPRF26 SPRF26M SPRF36 SPRF36M M2 SPRF86 SPRF86M2 SPFZ25 Freezer User Manual BEFORE USE PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS Felix St...

Page 2: ...ons 4 Technical Information 5 Location of Parts 6 Before your First Use 7 Installation 7 Electrical Connection 7 Setting the Temperature 8 Celsius Temperature Readout 8 Energy Saving Tips 9 Cleaning 9...

Page 3: ...Do not attempt to repair or replace any part of your appliance unless it is specifically recommended in this manual All other servicing should be referred to a qualified technician The SPFZ25 is CFC...

Page 4: ...temperature The SPRF26 and SPRF36 series can safely hold medical supplies within their required temperature range of 2 8 C and as low as 15 C while the SPRF86 series is designed to safely protect refr...

Page 5: ...ght 35 lbs Unit Dimensions 21 3 W x 14 4 D x 21 7 H Model Numbers SPRF86 SPRF86M2 Capacity 80 liters 2 8 ft3 Electrical Input DC 12 24V AC 120 220V Power Input Approx 55W Net Weight 59 5 lbs Unit Dime...

Page 6: ...with an interior load line It is recommended to store items below that line to achieve storage temperatures from 15 C to 20 C NOTE Pack vaccines or more temperature sensitive materials at the bottom...

Page 7: ...4 Never locate the unit anywhere the ambient temperature is below 0 C 32 F or above 30 C 86 F CAUTION Allow the unit to sit upright for 24 hours before turning it on to allow the compressor lubricant...

Page 8: ...hear the sound of the compressor starting 5 Press the UP button or the DOWN button to adjust the temperature Pressing either button with adjust the temperature by 1 C NOTE The compressor will shut of...

Page 9: ...l help keep mold from forming and prevent stale odors It is a good idea to follow the cleaning procedure below before storing your cooler CLEANING Clean your unit with a soft cloth moistened with luke...

Page 10: ...tilator or propeller is blocked Clean the ventilator and the propeller and make sure the unit has good ventilation There is a strange noise or vibration during operation The unit is malfunctioning To...

Page 11: ...11 NOTES...

Page 12: ...units operated outside the United States 5 Repairs to parts or systems resulting from unauthorized modifications made to the appliance 6 Expenses for travel and transportation for product service in...