17
Display “E0”,
“E1”. “E2”,
“E3”, “E4”,
“E5” or “E7”.
•
“E0” indicates a communication error
for 3-zone models.
•
“E1” or “E2” indicates that the air
temperature sensor has failed.
•
“E3” or “E4”indicates that the defrost
sensor in the evaporator has failed.
•
“E5” indicates a defrost heater failure.
•
“E7” indicates a door switch failure.
•
Call for service.
The alarm
sounds and
the
temperature
display
flashes.
Has the appliance door been open for
longer than 60 seconds? If not, then the
temperature has risen higher or fallen
lower than the temperature that has been
set. This could be due to:
•
The appliance door being opened too
often.
•
The ventilation opening being covered
or too dusty.
•
A lengthy interruption in the power
supply.
•
A large amount of content has been
added to the unit.
If yes, close the door.
•
Do not open the door more often than
necessary.
•
Clear the obstructions and clean the
dust.
•
Leave the appliance to work for a
while until the set temperature has
been reached.
The icon “--” is
lit and flashing
in the
temperature
display.
•
The display temperature is out of
range.
•
Only temperatures within the range
0~99°F/-9~37°Cfor ACR45L and the
range -49~99°F/-45~37°C for
ACF33Lcan be displayed. If the
temperature is not within this range,
the icon “--” will be displayed instead.
This is normal.
If you've checked the table above and find that you still need help with your appliance, call our Customer
Service facility at
800-932-4267
between 9:00AM and 5:00PM ET. We will do our best to answer your
questions.
This product uses eco-friendly hydrocarbon refrigerant and fully complies with California
CARB regulations.
However, we are required by California Law to provide the following disclosure statement in every
product sold in California.
"This equipment is prohibited from use in California with any refrigerants on the 'List of Prohibited
Substances' for that specific end-use, in accordance with California Code of Regulations, title 17,
section 95374. This disclosure statement has been reviewed and approved by Felix Storch, Inc.
and Felix Storch, Inc. attests, under penalty of perjury, that these statements are true and
accurate
."
This product does
not
use any refrigerants on the 'List of Prohibited Substances'"