background image

 

 

12 

 

 

TOTAL 70

 

1880

 

No   Value

 

SN

 

01/5

 

3. Equipment Overview (continued) 

 

3.3 Control Panel Description (continued) 

 

 

SHOW

: Show COUNTING REPORT & SERIAL # REPORT 

Press SHOW one time to access the “Counting report” then press it again 

to show the “Serial # report”. Press it again to return to the counting 

screen. 

 

**Note: 

If the serial number report is longer than what is immediately shown 

on the screen, then use the                keys to view the rest of the report. 

 

 

 

1

 

1

 

AD77883667

 

2

 

1

 

XC23456789

 

3

 

10

 

WE87345678

 

4

 

50

 

NV56782309

 

5

 

20

 

GH99837665

 

6

 

20

 

DF74092287

 

7

 

20

 

AF17385654

 

 

 

 

 

 

DEN    PCS  $ 

x  10 

10 

x  10 

20 

x  10 

50 

10  x  10 

100 

20  x  10 

200 

50  x  10 

500 

100  x  10 

1000 

 

 

Counting Report 

Serial Number Report 

Summary of Contents for SWITCH AB7800

Page 1: ...AB7800 SWITCH Comprehensive Bill Counter USER GUIDE www AccuBANKER com...

Page 2: ...Thank you for trusting AccuBANKER with your cash handling needs In order to optimize the performance of your equipment we encourage you to thoroughly read this user guide prior to use...

Page 3: ...ction 16 4 2 Settings Allows the user to configure several functions 17 4 3 TIME SET Date and Time adjustment 19 4 4 UPDATE Reserved for Technical Service 19 4 5 SERVICE 20 4 6 USERS 21 5 Operation 22...

Page 4: ...rate and reliable but its mixed bill counting counterfeit detection easy to use touch screen and dual user functionality make it suitable for a wide range of cash management tasks Box Contents 1 AB780...

Page 5: ...y result in electric shock fire or cause serious damage to the unit Do not operate the unit in areas with high temperature or high humidity sinceit may prevent it from working correctly Caution When u...

Page 6: ...ll liquids of any kind on the product Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions When the power supply cord or plug is d...

Page 7: ...lect an appropriate workspace that is clean flat and leveled The equipment should never be placed near strong sources of light heat sources or air conditioners Please do not install the equipment wher...

Page 8: ...folded or damaged bills B Check for foreign objects mixed up with the bills such as paper clips rubber bands pieces of paper etc C If counting new bills fan them lightly since they often stick togeth...

Page 9: ...ickness Adjustment knob Used to adjust the bills feeding gap The opening where bills enter the equipment from the hopper 8 Upper Module Handle Pulled to access inside upper compartment 9 Sensors Tray...

Page 10: ...erating mode 2 Denomination breakdown 3 Quantity of rejected bills 4 Currency 5 Total value of counted bills 6 Quantity of bills counted 7 Date and Time 1 MIX DEN PCS 1 x 10 2 x 10 5 x 10 10 x 10 20 x...

Page 11: ...Reset BATCH Batch mode selection Press BATCH continuously to select from the pre set options See section 3 4 for more detailed instructions to enter a Batch quantity manually using the VALUE function...

Page 12: ...ial report Press it again to return to the counting screen Note If the serial number report is longer than what is immediately shown on the screen then use the keys to view the rest of the report 1 1...

Page 13: ...tings MENU BACK Press MENU BACK to access the User Menu to set up this equipment or to go back to a previous screen Refer to Section 3 for a full description of the User Menu options ERROR Press ERROR...

Page 14: ...ls counted FACE Use to sort bills by either FACE UP or FACE DOWN The equipment will memorize the position of the first bill in the count and send it to the stacker Bills facing in the opposite positio...

Page 15: ...need to be adjusted on the equipment a password needs to be set up etc a Press VALUE to access the numeric screen b Press CLR to clear the current value c Enter the new desired value d Press OK on the...

Page 16: ...in section 3 3 4 1 Currency Selection Select the specific operator I or II Press MENU on the control panel Press Currency on the touch screen Select the desired currency and press START for the desir...

Page 17: ...e Bill detection adjustment Press VALUE to change the current sensitivity Press CLR to clear the current setting enter the new value and press OK to confirm DB 0 is OFF DB 9 is Maximum DB 5 default d...

Page 18: ...n as it detects bills have been placed on the hopper On Manual the unit will begin the count when START is pressed by the user Press VALUE to change the current setting Press CLR to clear the current...

Page 19: ...the current value and enter the new one d Press OK to confirm e After modifying all the required fields press continuously until the message SET OK is shown then press BACK to return to the counting s...

Page 20: ...ifetime f Password Set Password Enable 1 Password Disabled 0 Enable 1 or Disable 0 the option to protect the User Menu by a password in order to avoid unauthorized access to the unit s setting configu...

Page 21: ...e YES option and press ENTER to begin the restore process When the message Flash Disk Format Finish is shown the restore has been completed Press BACK to return to the counting screen 4 6 USERS Shows...

Page 22: ...ounting them automatically unless the Manual option has been selected within the settings Note Those bills considered suspicious will be rejected and sent to the rejection tray during the counting pro...

Page 23: ...r a brush remove the dust deposited on the hopper and the stacker area Weekly routine Perform the following steps on a weekly basis a Turn off the unit and unplug its power cord b Open the back cover...

Page 24: ...and Paper made bills counted together Having the correct feeding gap will ensure a smooth counting as well as a trouble free unit s operation Trial and error attempts are recommended before you make...

Page 25: ...Settings Go to the SERVICE section in the User Menu then select RESTORE FACTORY SETTINGS This procedure will restore the factory default settings for the Counterfeit detection functions NOTE Full pro...

Page 26: ...jects such as scissors letter openers knives etc a Proceed to open the specified compartment using its handle b If the user can easily reach the bill with his her fingers then proceed to remove it car...

Page 27: ...s down the MENU key then select the SERVICE option and press ENTER then select the 2 CIS Calibration option and press ENTER c Open the back compartment and position the calibration card all the way in...

Page 28: ...uter to export the counting information and save it To download the free version of the ABSuite access the link www accubanker com collections software then follow the installation instructions descri...

Page 29: ...ucing MG sensitivity Chain Note Two or more bills passed together partially overlap Adjust thickness adjustment knob Verify the bills fitness quality DB Error Two or more bills passed together one on...

Page 30: ...sor Clean the sensor Contact tech support L_U_IR ERR Upper Left Counting Sensor Clean the sensor Contact tech support Stacker ERR Stacker Sensor Dirty or Damaged Clean the sensor Contact tech support...

Page 31: ...r Capacity 200 bills new bills Rejection Tray 50 bills Max Bill size range 10 x 5 18 x 8 cm Display Touchscreen LCD Display Power Source 100 240 VAC 60 50 Hz Power Consumption 50 Watts Max standby 5W...

Page 32: ...AccuBANKER USA 7104 NW 50th St Miami FL 33166 9AM 5PM ET Monday through Friday www AccuBANKER com Please give us a call at 1 888 993 2228...

Reviews: