9
4. Operation
4.1 Basic Operation
1.
Connect the power cable to the detector and then connect the
adapter to the power outlet. When turning on the detector, it will
proceed with a self-check routine that lasts 2 seconds. The display
will light the green indicator , which means the equipment is
ready to check the bills.
2.
Insert the bill to be checked in any direction. When a bill is
inserted into the detector's feeding channel, an optical sensor
located in this compartment allows the detector to automatically
begin the verification process. The bill will be transported inside
the unit and analyzed immediately.
3.
If the bill is genuine, the green indicator will light up and
sound a single warning beep.
4.
If the bill is suspicious, the red indicator will light up and
sound two warning beeps.