24
7. Warning and Error Messages
The unit will notify the user if an error is detected during the booting up
procedure or in case any abnormal incident occurs during the operation.
Proceed as the table indicates for each error message.
ERROR
CAUSE
SOLUTION
UV Error
Suspicious UV
feature
-
Remove the suspicious bill
-
Consider reducing UV sensitivity
MG Error
Suspicious MG
feature
-
Remove the suspicious bill
-
Consider reducing MG sensitivity
Chain Note
Two or more bills
passed together
(partially overlap)
-
Adjust thickness adjustment knob
-
Verify the bill’s fitness quality
Double Note
Two or more bills
passed together (one
on top other)
-
Fan the bills
-
Adjust thickness adjustment knob
-
Consider reducing IR sensitivity
IR Error
Suspicious IR
feature
-
Verify the specific bill
-
Consider reducing IR sensitivity
Half Error
Check for a
mutilated bill
-
Remove the specific bill
Slant
The bill was fed tilt
and the angle is
higher than the
tolerance
-
Repeat the count or readjust
SLANT tolerance
Image Error
Suspicious note by
CIS Image detection
(stained, crimped,
etc.)
-
Try to pass it again
-
If persist verify it manually
Denomination
Different
In SORT mode a
different
denomination was
detected
-
Set it aside