Accu-Scope 3000-LED-SPH Manual Download Page 16

3000-LED MICROSCOPE SERIES 

ACCU-SCOPE

®

16

 

TECHNICAL SPECIFICATIONS 

Objectives 

Optical 
system 

AIS E-Plan optical system 

Head 

Siedentopf binocular viewing head, inclined 30

 

Eyepiece 

PL10X/20mm diopter adjustable eyepiece, 20mm field of view  

Nosepiece 

Reversed quadruple nosepiece 

Objective 

AIS E-Plan achromat objective

4X, 10X, 40X, 100X

 

Focusing 
system 

Coaxial coarse & fine focusing system, with stop limit & tension adjustment.   
Travel range: 25mm. Fine focusing precision: 0.002mm 

Stage 

Built in low position coaxial control mechanical stage, area 140x132mm, moving range 
76x50mm 

Condenser 

Built-in Koehler illuminator systems, Pre-centered. 
Iris diaphragm Koehler illuminator condenser and mirror optional. 

Illuminator 

Universal power supply 90

240V voltage, 3W LED light with variable intensity control 

Operation 
Environment 

Indoor use

Altitude: max. 2000m

Environment temperature: 5

-40

41ºF-109ºF

Max. relative humidity: 80% at 31

88ºF

, and then declined linearly. 70% at

34

93ºF

, 60% at 37

99ºF

, 50% at 40

104ºF

.

Degree of pollution: 2 ( refer to IEC664)

Type

 

Objective

 

Numerical

 

aperture

 

(N.A.)

 

Conjugate

 

distance

 

(mm)

 

Parfocal

 

distance

 

(mm)

 

Thickness

 

of

 

the

 

cover

 

slip

 

Magnification

 

market

 

(color

 

ring)

 

Infinity

 

Plan

 

achromatic

 

objective

 

4X

 

0.10

45

 

0.17

 

Red

 

10X

 

0.25

45

 

0.17

 

Yellow

 

40X(S)

 

0.65

 

∞ 

45

 

0.17

 

Light

 

Blue

 

100X(S)

 

oil

 

1.25

 

∞ 

45

 

0.17

 

White

 

Summary of Contents for 3000-LED-SPH

Page 1: ...MANUAL 3000 LED MICROSCOPE SERIES 100 Lauman Lane Suite A Hicksville NY 11801 Tel 877 877 7274 Fax 516 801 2046 Email Info nyscopes com www microscopeinternational com LVWULEXWHG E...

Page 2: ...4 5 ASSEMBLY DIAGRAM PROCEDURE 6 8 ADJUSMENT OPERATION ILLUMINATION 9 MIRROR 9 SPECIMEN SLIDE 9 FOCUSING 10 INTERPUPILLARY DISTANCE 10 FIELD DIAPHRAGM 11 APERTURE DIAPHRAGM 11 OIL OBJECTIVE 12 FILTER...

Page 3: ...ctives or focusing assembly 2 Keep the instrument clean remove dirt and debris regularly Accumulated dirt on metal surfaces should be cleaned with a damp cloth More persistent dirt should be removed u...

Page 4: ...t quality prior to shipment UNPACKING AND COMPONENTS Your microscope arrived packed in a molded Styrofoam container Do not discard the container the Styrofoam container should be retained for reshipme...

Page 5: ...CROSCOPE SERIES ACCU SCOPE 5 COMPONENTS DIAGRAM Lock Screw Y Axis Adjustment Knob Coarse Focusing Knob Fine Focusing Knob X axis Adjustment Knob Power Switch Iris Diaphragm Adjustment Control Objectiv...

Page 6: ...preassembled by our factory technicians at our New York facility prior to shipment Should you need to disassemble assemble your microscope in the future please follow the instructions outlined below...

Page 7: ...oosen the condenser lock screw Insert the condenser into the hole of the stand according to the directional arrow until the condenser is even with the stand and then rotate the condenser to make sure...

Page 8: ...r of power cord securely into the power socket see Fig 3 Insert the other connector securely into an electrical outlet The microscope uses a universal power supply so it may be used in any voltage ran...

Page 9: ...power switch to the 0 off position Loosen the Allen screw with an Allen wrench to screw off the built in illuminator housing see Fig 5 Screw on the mirror according to the directional arrow and tight...

Page 10: ...your left eye only and the 10X objective focus your specimen by adjusting the coarse adjustment knob When the image is in view refine the image to its sharpest focus by turning the fine adjustment kn...

Page 11: ...r Illuminator Condenser Optional Adjusting the Aperture Diaphragm The aperture size is increased or decreased by rotating the condenser aperture diaphragm lever When the aperture is closed the brightn...

Page 12: ...xR oil immersion objective is in the light path With your eye at the level of the stage use the coarse focus knob to raise the stage with the specimen cover glass When you see a flash of light at this...

Page 13: ...ugh side downward onto the groove of the illuminator condenser Place the cover back on the illuminator condenser and re install the set screw Fig 13 Filters are available in clear blue frosted blue gr...

Page 14: ...rn the main switch to 0 OFF before replacing the LED bulb Unplug the power cord from the microscope Gently place the microscope on its arm as shown in Figure 15 Using a Philips head screwdriver remove...

Page 15: ...ulb in position and screw it to its mount Figure 19 Figure 18 above Reinstall the base plate and reconnect the make break connector with the connector from the new bulb Figure 20 Secure the base plate...

Page 16: ...range 76x50mm Condenser Built in Koehler illuminator systems Pre centered Iris diaphragm Koehler illuminator condenser and mirror optional Illuminator Universal power supply 90 240V voltage 3W LED lig...

Page 17: ...e objective correctly into the optical path Dirt or dust on the view field Dirt or dust on the lens eyepiece condenser objective collector lens or specimen Clean the lens Poor image quality No cover g...

Page 18: ...dial and or iris diaphragm Insufficient brightness Lamp intensity is too low Aperture diaphragm closed too far Condenser position too low Adjust the light intensity by rotating the intensity control...

Page 19: ...No electrical power Lamp bulb burnt out Fuse blown out Check power cord connection Replace bulb Replace fuse Slippage of focus when using the coarse focusing knob Tension adjustment is set too low Inc...

Page 20: ...years from the date of invoice to the original end user purchaser The LED lamp is warranted for a period of two years from the date of invoice to the original end user purchaser This warranty does no...

Reviews: