Main menu
Test
Turn off
Memory
Settings
Result
Set flag
All results
Time/Date
Tones
Reminders
Target range
Volume
Control test
Color
Averages
Time
Beeper
New
Turn on Turn off
General
On Off
All results
7 days
Date
Reminders
Edit
Change
Brightness
Before meal
On Off
Before meal
14 days
Time format
Acoust. mode
In 1 hour
Turn on Turn off
Cancel
After meal
On Off
After meal
30 days
In 2 hours
Change
Language
Reminder
Reminders
Transfer data
In 3 hours
Delete
For analysis
Cancel
Table to PC
Display format
Single value
List
Main menu
Tools
Display check
Validity
Clean
Change cass.
Preparing the lancing device for obtaining
new blood sample:
load new lancet
When all 6 lancets have been used:
remove lancet drum
Changing an empty cassette
Push lever to right and back again
1
Remove cap
2
Pull out drum
1
Open tip cover
2
Release cassette
compartment cover
3
Open cassette
compartment cover
4
Remove empty
cassette
5
Insert new cassette
9
Press
button
6
Close cassette
compartment cover
10
Press
button
7
Press cover to close
11
Main menu is
displayed
8
Press
button
12
Close tip cover
CLICK
Functions of the buttons
Adjust settings
Overview of the meter
Overview of the lancing device
Menu overview
Turning meter on or off
Press
button
Moving down a menu
Press
button
1
Turn on meter
4
Select
Settings
Executing a command
Press
button
Counting upwards
Press
button
2
Wait for displays
5
Open
Settings
Counting downwards
Press
button
Moving up a menu
Press
button
3
Main menu
is displayed
Settings
menu overview
press and hold longer than
2 seconds
press and hold
longer than 2 seconds
1
Battery compartment cover (right: from above; far
right: open)
2
Infrared window
3
Batteries [1.5 V, type AAA, alkaline-manganese or
high energy batteries (2 batteries required)]
4
Lancing device (docked)
5
Tip cover (bottom: open)
6
Test area (at the tip of the cassette ready for a test)
– this is where you apply the blood
7
Down/Up buttons
8
On/Off and Enter button
9
Display
10
Release button for undocking the lancing device
11
Type plate
12
Release button for opening the cassette compart-
ment cover
13
Cassette compartment cover (right: open)
14
Test cassette (in place in the meter)
15
Multifunction button (priming and lancing)
16
Lever for rotating the lancet drum and loading a new
lancet
17
Lancet drum containing 6 lancets
18
Numbers indicating penetration depth settings
19
Rotatable cap (rotating the cap on the device sets
the penetration depth)
20
Pin-hole opening for lancet
21
Penetration depth indicator
22
Window showing number of available lancets
Select with
Open or set with
This Quick Reference Guide is not a substitute for the full User’s Manual supplied with your
Accu-Chek Mobile blood glucose meter.
Please be sure to observe the safety information in the User’s Manual.