Accton Technology Zilla Dual-Speed Hub-3008R Quick Installation Manual Download Page 5

Quick Installation Guide

5

2. Install a 10 or 100 Mbps (10BASE-T or 100BASE-TX)

network adapter card and driver in each
computer you want to network.

3. Prepare straight-through

twisted-pair cables with RJ-45
plugs. Attach one end of the
cable to the RJ-45 port of the
computer’s network adapter
card and the other end to any
available port on the hub.

Notes:

 If you are using port 8, be

sure the Daisy-Chain switch is set to "COMPUTER."

Cascade Devices to the Hub

If you need more ports, connect a station port on another
device to the cascade port on the Zilla hub with straight-
through twisted-pair cable, maximum 5 meters (19.68 feet).

1.

To make a direct connection to another compatible hub or
switch, use the RJ-45 cascade port 8. Set the port
selection switch to HUB and then
connect to any station port on the
other device.  Alternatively, you
can connect from any RJ-45
station port on the hub to an
uplink port on the other device.

2. Prepare straight-through shielded

or unshielded twisted-pair cables
with RJ-45 plugs at both ends.
Use 100

Š

 

Category 3, 4 or 5

cable for standard 10Mbps
Ethernet connections, or 100

Š

Category 5 cable for 100Mbps Fast
Ethernet connections.  When inserting an RJ-45 plug, be
sure the tab on the plug clicks into position to ensure that
it is properly seated.

Notes:

1. Make sure each twisted-pair cable does not

exceed 100 meters (328 feet).

2. To connect to another hub or switch, you may

also attach to station ports at both ends if you
use crossover cabling.

Summary of Contents for Zilla Dual-Speed Hub-3008R

Page 1: ...Zilla Dual Speed Hub 3008R Quick Installation Guide...

Page 2: ......

Page 3: ...s completely plug and play no configuration necessary This dual speed hub contains two internal repeater buses one for 10Mbps traffic and another for 100Mbps traffic Traffic passing between attached d...

Page 4: ...pair cabling to any station port on this hub Port 8 doubles as a station computer port and a cascade uplink port The cascade port makes it convenient to connect cable from the hub to a station port on...

Page 5: ...a direct connection to another compatible hub or switch use the RJ 45 cascade port 8 Set the port selection switch to HUB and then connect to any station port on the other device Alternatively you ca...

Page 6: ...s a l F t r o p e h t g n i s r e v a r t s i c i f f a r T Troubleshooting Symptom Power LED does not light after power on Cause Power outlet or power cord may be defective Solution 1 Check for loos...

Page 7: ...Quick Installation Guide 7 Application Diagram...

Page 8: ...ine speed Forwarding Rate 14 810 pps at 10 Mbps 148 810 pps at 100 Mbps Learning Rate Line speed Dimensions 90 x 97 5 x 24 mm Weight 160 gm Power Requirements 10 VDC 0 6 A from external power adapter...

Page 9: ...antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from the one which the receiver is connected to Consult the dealer or an...

Page 10: ...SPR 22 1985 class B EN60555 2 1995 class B EN60555 3 IEC1000 4 2 1995 4kV CD 8kV AD IEC1000 4 3 1995 3V m IEC1000 4 4 1995 1kV power line 0 5kV signal line IEC1000 4 6 1995 3Vrms This product complies...

Page 11: ...ht benutzt sollten Sie es vom Stromnetz trennen Somit wird im Falle einer berspannung eine Besch digung vermieden 12 Durch die L ftungs ffnungen d rfen niemals Gegenst nde oder Fl ssigkeiten in das Ge...

Page 12: ...purchased this product install it THE ABOVEWARRANTY IS IN LIEU OF ANY OTHERWARRANTY WHETHER EXPRESS IMPLIED OR STATUTORY INCLUDING BUT NOT LIMITEDTO ANYWARRANTY OF MERCHANTABILITY FITNESS FOR A PARTI...

Reviews: