Accton Technology CheetaHub Power-3012B Installation Manual Download Page 6

CheetaHub Power-3012B User’s Guide

iv

Quick Installation

4.

 

Connect PCs or other network devices to the RJ-45 ports.

Attach PCs or daisy-chain to
another device via the RJ-45 ports

Connect any devices that use standard network interface
cards to the RJ-45 (MDI-X) station ports (e.g., a workstation,
server, bridge or router).  This hub uses auto-sensing to
dynamically set the required transmission speed at 10 Mbps
or 100 Mbps for the RJ-45 ports.  To cascade to another hub
or switch, run straight-through twisted-pair cable from the
MDI port (10/100 Mbps) on this hub to any (MDI-X) station
port on the other device (or vice versa).  If necessary, you
can also cascade to another hub or switch by running
crossover cable between MDI-X ports on the two devices.

Use the correct
twisted-pair cable

Use unshielded twisted-pair (UTP) or shielded twisted-pair
(STP) cable for RJ-45 connections: 100

W

 Category 3, 4 or 5

cable for 10 Mbps connections or 100

W

 Category 5 cable for

100 Mbps connections.  Also be sure that the length of any
twisted-pair connection does not exceed 100 meters (328 feet).

Cascade limitations

When using the MDI port for 10 Mbps connections, note that
up to 4 hubs can be cascaded.  However, when using the MDI
port for 100 Mbps connections or when using two MDI-X
ports connected with crossover cable for 100 Mbps
connections, only 2 hubs can be cascaded.

Limit total network span

When connecting devices to the dual-speed hub, note that the
total network span must be limited to:

Single Hub

200 meters of twisted-pair cable

Two-hub Chain

205 meters of twisted-pair cable (for Fast Ethernet links)

For example, if two PCs are connected to a hub, each using
100 meters (328 feet) of twisted-pair cable, then the total
network span of 200 meters (656 feet) is within the allowed
limits.  However, if you cascade two Fast Ethernet hubs, and
connect a PC to each hub, each using 100 meters of cable, as
in the preceding example, then you can only use 5 meters (16
feet) of twisted-pair cable to link the two hubs together.  The
only way to extend the cabling that connects the hubs is to
reduce the length of cable used to connect the PCs to the hubs.

Summary of Contents for CheetaHub Power-3012B

Page 1: ...CheetaHub Power 3012B INO GG ODJI IP G...

Page 2: ...Installation Manual CheetaHub Power 3012B Ethernet Hub with 12 Dual Speed RJ 45 Ports and 1 MII Port Two Internally Switched Repeaters for 10 Mbps and 100 Mbps Domains in One Package...

Page 3: ...t to make revisions to this publication without obligation to notify any person or entity of any such changes International Headquarters No 1 Creation Road III Science based Industrial Park Hsinchu 30...

Page 4: ...ng four rubber foot pads installation manual warranty registration card AC power cord Please inform your dealer immediately should there be any wrong missing or damaged parts If possible retain the ca...

Page 5: ...ther internal repeater bus This hub provides an ideal bridge between 10 Mbps and 100 Mbps Ethernet networks all for a price that s comparable to a standard Ethernet or Fast Ethernet hub Moreover the s...

Page 6: ...connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet Cascade limitations When using the MDI port for 10 Mbps connections note that up to 4 hubs c...

Page 7: ...200 meters or 656 feet i e 100 meters for the downlink from the switch or router to the hub and 100 meters from hub to workstation However by attaching fiber optic cable to the MII port on the rear pa...

Page 8: ...nnections This manual covers the following topics Chapter 1 Product Overview Brief description of Fast Ethernet technology followed by a description of this hub and a summary of its important features...

Page 9: ...Making a Connection via the Daisy Chain Port 2 5 Restrictions on Cascade Length 2 6 Making a Connection via the MII Port 2 7 Providing Power to the Hub 2 8 Connecting to the Power Supply 2 8 Diagnost...

Page 10: ...y Control Council for Interference VCCI B D 2 EN55022 Declaration of Conformance D 2 Safety Compliance D 3 Underwriters Laboratories Compliance Statement D 3 Sicherheitshinweise D 4 Appendix E Product...

Page 11: ...e Hub Configuration Using Daisy Chain Port 3 3 Figure 3 3 Uplinked Hub Using Fiber Optic Cable 3 4 Figure B 1 RJ 45 Connector on the Hub Side B 1 Figure B 2 MII Connector B 2 List of Tables Table 2 1...

Reviews: