Mounting the Switch

This switch can be placed directly on your desktop, or mounted in a rack.
Before you start installing the switch, make sure you can provide the right operating

environment, including power requirements, sufficient physical space, and proximity

to other network devices that are to be connected.  Verify the following installation

requirements:
• Power requirements: 100 to 240 VAC (± 10%) at 50 to 60 Hz (± 3Hz).  The

switch's power supply automatically adjusts to the input voltage level.

• The switch should be located in a cool dry place, with at least 10 cm. (4 in.) of

space at the front and back for ventilation.

• Place the switch out of direct sunlight, and away from heat sources or areas with

a high amount of electromagnetic interference.

• If you intend to mount the switch in a rack, make sure you have all the necessary

mounting screws, brackets, bolts and nuts, and the right tools.

• Check if network cables and connectors needed for installation are available.

Stacking Switches on a Flat Surface

The CheetahSwitch can be stacked

anywhere there is a enough flat space,

such as on a table or desktop.
1. Stick the self-adhesive rubber foot

pads (that come with this package)

on each of the 4 concave spaces located on the bottom of the first switch.

2. Place the first switch on a firm flat surface where you want to install the stack.

3. Repeat step 1 for each switch before stacking them.  The rubber foot pads

cushion the switch against shock/vibrations and provide space between each

switch for ventilation.

Mounting Switches in a Rack

Please comply with the following

instructions to ensure that your switch

is securely mounted in the rack.
1. Use a standard EIA 19-inch rack.

2. Use the brackets and screws supplied

in the rack mounting kit.

3. Use a cross-head screwdriver to attach the brackets to the side of the switch.

4. Position the switch in the rack by lining up the holes in the brackets with the

appropriate holes on the rack, and then use the supplied screws to mount the

switch in the rack.

Connecting the Switch System

The CheetahSwitch has 24 RJ-45 ports and one AUI port that support connection to

standard 10 Mbps Ethernet.  It also has two slots for installing optional 100BASE-TX

or 100BASE-FX Fast Ethernet Uplink Modules.
All ports support full or half-duplex operation.  The transmission mode for the

10BASE-T, AUI and 100BASE-FX ports must be manually configured using the

configure button or console interface.  (See "Configuring the Switch" on page 7.)

The transmission mode can be set for the 100BASE-TX ports using auto-negotiation

(if also supported by the attached device).  However, if the devices attached to

these ports do not support auto-negotiation, you can manually configure the port to

match the transmission mode used by the attached device.  You can also set the

switching mode for any of the switch's ports to cut-through or store-and-forward

using the console interface.  (See “Using the Console Program” on page 7.)

Making a Connection via an MDI-X Station Port

You can connect any RJ-45 (MDI-X) station port on the switch to any device that

uses a standard network interface such as a workstation or server, or to a network

interconnection device such as a bridge or router (depending on the port type

implemented on that device).
1. Prepare the devices you wish to network.  Make sure you have installed

10BASE-T or 100BASE-TX network interface cards for connecting to the

switch's RJ-45 (MDI-X) station ports.  You also need to prepare straight-through

shielded or unshielded twisted-pair cables with RJ-45 plugs at both ends.  Use

100

W

 Category 3, 4 or 5 cable for standard 10 Mbps Ethernet connections, or

100

W

 Category 5 cable for 100 Mbps Fast Ethernet connections.

2. Connect one end of the cable to the RJ-45 port of the network interface card,

and the other end to any available (MDI-X) station port on the switch.  RJ-45 Ports

1 - 24 support 10 Mbps Ethernet connections (in addition to the AUI Port).  If you

ordered the 100BASE-TX uplink module, then you can also attach the switch to

a 100 Mbps Fast Ethernet device.  When inserting an RJ-45 plug, be sure the

tab on the plug clicks into position to ensure that it is properly seated.  Using the

switch in a stand-alone configuration, you can network up to 27 end nodes.

I

Do not plug a phone jack connector into any RJ-45 port.  This may damage the

switch.  Instead, use only twisted-pair cables with RJ-45 connectors that

conform with FCC standards.

Notes:

1. Make sure each twisted-pair cable does not exceed 100 meters (328 feet).

2. We advise using Category 5 cable for all network connections to avoid

any confusion or inconvenience in the future when you upgrade attached

devices to Fast Ethernet.

Making a Connection via the MDI Daisy-Chain Port

1. To make a direct connection to another compatible switch or repeater hub,

connect any RJ-45 (MDI-X) port on the switch to an MDI daisy-chain port on the

other device.  If you have a 100BASE-TX uplink module installed, then you can

link to another switch or hub by running a cable from MDI-X to MDI ports on

either device.  (See "Connecting to an Uplink Module" on page 4.)

2. Prepare straight-through shielded or unshielded twisted-pair cables with RJ-45

plugs at both ends.  Use 100

W

 Category 3, 4 or 5 cable for standard 10 Mbps

Ethernet connections, or 100

Category 5 cable for 100 Mbps Fast Ethernet

connections.  When inserting an RJ-45 plug, be sure the tab on the plug clicks

into position to ensure that it is properly seated.

Notes:

1. Make sure each twisted-pair cable does not exceed 100 meters (328 feet).

2. To connect to another switch or hub, you may also attach to (MDI-X)

station ports at both ends if you use crossover cabling.

3. To achieve best performance when cascading switches, group devices or

segments that communicate most frequently on the same switch, and

reserve the Fast Ethernet uplinks for connecting to the larger network.

Summary of Contents for CheetahSwitch Workgroup-2027

Page 1: ...CheetahSwitch Workgroup 2027 Quick Installation Guide ES2027 E0298 R03 150185 101...

Page 2: ...this document is subject to change without notice Accton reserves the right to make revisions to this publication without obligation to notify any person or entity of any such changes International He...

Page 3: ...or attached PCs all with conventional cabling and adapters It completely eliminates the bottlenecks of shared 10Mbps Ethernet networks by providing a wide bandwidth of up to 460 Mbps This makes it id...

Page 4: ...hing mode for any of the switch s ports to cut through or store and forward using the console interface See Using the Console Program on page 7 Making a Connection via an MDI X Station Port You can co...

Page 5: ...on However if the attached device does not support auto negotiation you can manually configure the connected port to half or full duplex using the configure button or console interface See Configuring...

Page 6: ...o t t r o p I U A m o r f e l b a c p o r d f o h t g n e l m u m i x a M 2 t e e f 4 6 1 s r e t e m 0 5 t e e f 4 6 1 s r e t e m 5 0 Configuring the Switch The transmission mode for all ports must...

Page 7: ...nsist of up to 14 alphanumeric characters and are case sensitive Restarting the System Use the Restart command to reboot the system Factory Reset Use this command to restore factory defaults and reboo...

Page 8: ...em link Troubleshooting Diagnosing Switch Indicators The switch can be easily monitored through panel indicators to assist the network manager in identifying problems This section describes common pro...

Page 9: ...r RJ 45 connections Category 3 or greater for 10 Mbps connections and Category 5 for 100 Mbps connections Class A Canada Department of Communications This digital apparatus does not exceed the Class A...

Page 10: ...icherheit nur von authorisiertem Servicepersonal ge ffnet werden 14 Wenn folgende Situationen auftreten ist das Ger t vom Stromnetz zu trennen und von einer qualifizierten Servicestelle zu berpr fen a...

Reviews: