Accora FloorBed 2 Instruction Manual Download Page 2

 

2  

© Accora: 01223 206100 | [email protected] | www.accora.uk.com 

Contents 
 
Title   

          

 

        Page 

 

Introduction   

 

 

 

 
1.

 

Means of delivery 

 

 

2.

 

Safety Instructions 

 

 

3.

 

Intended use   

 

 

4.

 

Technical specification 

 

5.

 

Accessories 

 

 

 

6.

 

Electrical specification 

 

7.

 

Assembly 

 

 

 

8.

 

Positioning 

 

 

 

9.

 

Functionality check   

 

10.

 

Using the castor brakes 

 

11.

 

Mattresses selection   

 

10 

12.

 

Siderail selection 

 

 

10 

13.

 

Disassembly   

 

 

10 

14.

 

Moving and Repositioning 

 

11 

15.

 

Cleaning & Disinfection 

 

11 

16.

 

Troubleshooting 

 

 

11 

17.

 

Storage 

 

 

 

12 

18.

 

Daily inspection 

 

 

12 

19.

 

General maintenance 

 

12 

20.

 

Guarantee 

 

 

 

12 

21.

 

Disposal 

 

 

 

12 

 

 

 

 

I

ntroduction

 

 
Dear Customer, 
 
Thank you for purchasing an Accora healthcare 
product. We feel sure that this product will 
exceed your expectations. 
 
This manual is important for realising the full 
potential of your new FloorBed; please read it 
before use. If you need further information, 
please contact us at: 
 
Tel: 01223 206100 
 
Fax: 01223 206120 
 
E-mail: [email protected] 

 

 

General 

The FloorBed is classified as a Medical 
Device Class 1 in accordance with 
93/42/EEC. 
 

 

The FloorBed nursing bed is designed to be 
used by patients in both low and high need 
care environments where medical supervision 
is required and monitoring is provided if 
necessary. 
 
Before operating the bed, you must become 
acquainted in detail with this manual. All 
actions and handling of the bed must be 
performed in accordance with the instructions 
in this manual. 
 
Any actions that are inconsistent with the 
manual are performed at your own risk and 
Accora shall not be liable for any injury or 
damage. Please ensure that the manual is 
available to operators throughout the bed’s 
service life. 

Summary of Contents for FloorBed 2

Page 1: ......

Page 2: ...is manual is important for realising the full potential of your new FloorBed please read it before use If you need further information please contact us at Tel 01223 206100 Fax 01223 206120 E mail inf...

Page 3: ...electric hazards The bed must not be used if there is any visible damage to the handset or cable 13 Inappropriate use of the power supply cord e g kinking shearing could lead to dangerous electric ha...

Page 4: ...trapped 11 If a lifting pole or infusion stand is fixed to the bed increased attention must be taken during movement lifting or tipping to the space around the lifting pole and infusion stand so that...

Page 5: ...rking load is calculated as follows as specified by EN 60601 2 52 Maximum patient weight 150kg 23 5st 330lb Mattress 20kg 3st 44lb Accessories 15kg 2 5st 33lb TOTAL Safe working load 185kg 29st 407lb...

Page 6: ...ress platform head section c Mattress platform foot section d Footboard e Headboard WARNING Assembly MUST be carried out by a competent person All functions MUST be tested and approved by a competent...

Page 7: ...sert locking pin and R clip as shown in two positions 6 Insert two mattress platform joining bars and secure with locking pins and R clips as shown in two positions 7 Join the two parts of the bed tog...

Page 8: ...oned If the medical staff state that the patient s medical condition is inappropriate for the patient to be able to adjust the bed independently the bed s position must be adjusted by the carer Please...

Page 9: ...it stops in the Safety Stop position button 6 c Use the safety double button function to lower the bed to the Floor level position buttons 6 7 pressed together d Check all cables for risk of crushing...

Page 10: ...s shown in Section 7 a Footboard b Headboard c Mattress platform foot section d Mattress platform head section 9 Ensure all R clips and pins are refitted so that the bed on the transport bracket is sa...

Page 11: ...ean as described in the Cleaning Information 16 Troubleshooting The FloorBed does not function correctly 1 Is the Power on indicator light on the handset lit If not a Is the power supply plugged in an...

Page 12: ...thin the scope of the Lifting Equipment Operations Regulations LOLER and so there is no formal legal requirement for regular inspection by a LOLER competent person The following checks must be carried...

Page 13: ...dance RF emissions CISPR 11 Group 1 The bed uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equi...

Page 14: ...1kV line s to line s 2kV line s to earth 1kV differential mode Not applicable Mains power quality should be that of a typical commercial or hospital environment Voltage Dips short interruptions and v...

Page 15: ...d strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range Interference may occur in the vicinity of equi...

Page 16: ...smitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2...

Page 17: ...1 2010 We Accora Ltd Of Charter House Barrington Road Orwell Cambridge SG8 5QP hereby declare that Model reference FloorBed 2 Serial No Refer to product label conforms to the Requirements of Directive...

Page 18: ...20 Accora 01223 206100 info accora uk com www accora uk com IFU FB2 001 EN Rev 1 JAN 2016...

Page 19: ......

Reviews: