7
www.acclaimlighting.com
FLEX EXTERIOR LINE CHANNEL (FLK EXL)
This sturdy anodized aluminum channel allows the Flex One tape to be recessed into
Exterior surfaces and is rated for walk-over installations. Thanks to the increased thickness
of its profile, the channel can withstand pressures of up to 2.9psi (20kN/m
2
). To achieve
effective IP67 water ingress protection it is necessary to use Dow Corning® 799, 1199 (or
equivalent) silicone sealant to form complete seals between the channel and its UV coated
lens - plus any cable access holes. For channel dimensions, see page 26.
Options
TO FIT THE FLEX ONE TAPE
Note: The molded feed cap fitted on each spool is too large to fit within the channel. In order to
achieve a fully sealed installation within the channel, it will be necessary to remove the molded
connection and solder new feed wires directly to the nearest cut line. See page 5.
1 If necessary, cut the channel to the required length. Ensure that any resulting burrs are
removed.
2 Ensure the tape mounting surface within the channel is
completely dry and clean.
3 Determine the length of tape required. Mark the
positions at each end of the channel where
the tape will be placed.
Note: Flex One tape can be cut every
1” (25mm), which may slightly
constrain the precise lengths of tape
that can be achieved. Therefore, it
may be beneficial to center the tape
within the channel to achieve an even
distribution.
4 Cut the tape to the nearest
marked cutpoint.
5 Carefully push the tape into the
channel, starting at the marked position. The tape’s size will cause an interference fit
within the channel, keeping it in place without adhesive.
IMPORTANT: While pressing the Flex One tape into position, take care not to put
excessive pressure on the components or connections.
6 Use Dow Corning® 799, 1199 (or equivalent) silicone sealant to fully encapsulate the feed
connections to protect against any moisture ingress.
Flex Exterior line channel
(3.28’ / 1m)
[FLK EXL]
End cap
[FLK EXL EC]
Exterior line opal lens
(3.28’ / 1m)
[FLK EXL OL]
End cap with hole
[FLK EXL ECH]
+24
V
+24
V
+24
V
+24
V
+24
V