System Command Description:
Only in configuration mode:
Change Master PIN Code
Change the 8-digit master PIN Code
E.g. to change Master PIN to 12345678 enter:
"
12345678
"
Add new User – Easy Enrolment
By default no users have to be added. The
reader forwards all Bluetooth ID on the
Wiegand bus. Add users if a personal PIN code
is required.
Command must be executed on the users
mobile phone. It adds the used mobile phone to
the specified storage position.
E.g. add user with PIN code 1234 on position 3
enter: "
03,1234
"
Change System Configuration 1
This command handles Wiegand facility code,
Wiegand type. 10 different formats are
supported. Default is Wiegand 26.
See User Manual for details
Change System Configuration 2
This command handles system detection range
and I/O configuration. See User Manual for
details.
System Command Description:
By administrators or in configuration mode:
Add new User
By default no users have to be added. The
reader forwards all Bluetooth ID on the
Wiegand bus. Add users if a personal PIN code
is required.
Adds a new user on the specified storage
position. The users Bluetooth address must be
entered. Deletion of current user is not required
E.g. add user with ID 0022b4b62918 and PIN
code 1234 on position 1 enter:
"
01,0022b4b62918,1234
"
Delete User
Deletes the user on the specified storage
position.
E.g. delete administrator stored on position 1
enter: "
01
"
Execute System Commands
See description below
Execute System Configurations
See description below
Execute System Commands:
Some predefined system commands.
“
E01
” - Performs a System Reset
“
E02
” - Performs a Factory Reset
“
E03
” - Enter Configuration Mode
“
E04
” - Performs a Factory Reset and enters
Configuration Mode (“E02” + “E03”)
“
E05
” - Erases the complete user list and adds
the default Any user “FFFFFFFFFFFF” on
storage position 01 as new administrator
“
E06
” - Increases the RX range to allow access to
the users further away (+3 dBm steps)
“
E07
” - Decreases the RX range to allow the
users to be closer to the reader before
access (-3 dBm steps)
Execute System Configurations:
Some predefined system configurations which
helps adjusting the system to the required
detection distance.
“
C01
” - Very short range ≈ 10 cm
“
C02
” - Door access - short ≈ < 50 cm
“
C03
” - Door access - normal ≈ < 2 m
“
C04
” - Gate access ≈ < 5 m
“
C05
” - Gate access - long ≈ < 10 m
“
C06
” - Very long range ≈ < 100 m
The specified distance is indicative only and will
depend on actual installation.
Smart Phone Apps:
An AccessZone Administrator app helps building
up the system commands. App is available for
iOS and Android.
Please see our web page for further details:
http://www.mvc-data.com/Smart_Phones.html
Example with iPhone