
Figure 18
Figure 19
3) Motor current auto-detection
The LED display shows the current consumption of the motor "0.4" : During the system learning procedure, the control panel will automa-
tically detect the current consumption from each motor, indicate the resistance level of the gate whiling the motor operation. If this
reading increase instantly or stay in high reading, please check if any object in between of the gate moving area, and contact your installer
for inspection.
Warnings
2) To Reset Factory Setting:
Press UP and DOWN for 3 seconds, and the LED display shows “CL”
1
9
Programmable Functions
LED Display
“-L”: The system learning is not done.
“OP”: The system is in normal operation To
the LED display change from OP to 1, press
UP or DOWN to change function settings (1
to P). Then press SET to enter the sub
function within each group, press UP or
Down to select sub functions and press SET
for confirmation.
“LE”: Enter learning mode and then wait for
learning instructions.
“LP”: The system learning is in progress.
The Auto-learning process of gate moving:
“Gate open to the end- stop close to the
end- stop.”
“CL”: Reset Factory Setting.
Programmable Functions
LED Display
Opening your life
Infinity
624