3
Factory Reset and Set management card
Connect the two pink wires
,
then power on. After the sound, Factory reset is finished. When indication LED turns green
,
it means you can set two
admin cards now
,
read the first card as admin add card
,
the second card as admin delete card
,
then LED turns red flash
,
after this, this device can
work resetting to factory default.
Note
:
Reset factory default wont delete user cards, If you present the same card when second read, the device will sound error reminding, then you
can continue present another card. If no operations within 10seconds, the device will enter working mode automatically parameter reset to factory
default.
4
Admin setting on keypad
Entering admin operating mode:
Press * Master code # factory default:999999
Note
:
All the below operations need be under programming mode.
4.1 Change the master code
:
Press 0 new code # repeat new master code ?????? #
Note: Master Code length:6~8 digits
4.2
Add users by remote control
:
4.2.1 Read card to add user
:
Press 1 read card # read card ... #
4.2.2 Use ID Number to add user
:
Press 1 card number # ... card number # ... #
Note: 1.Card number must be 8 or 10 digits, if the card number is less than 8 or 10 digits, input 0 before the card number
2.
Press # confirm
,
press last # finish
,
press * exit
。
4.2.3 Add consecutive number card.
:
Press 1
card quantity#
8 or 10 digits card number
Add consecutive number cards users
,
card quantity 1-9999
,
green fast flash
。
4.3
Delete users via remote control
:
4.3.1
Read card to delete user
:
Press 2 read card read card … #
。
4.3.2
Use card NO. to delete user
:
Press 2 8 or 10 digits card number # 8 or 10 digits card number # … # .
4.3.3
Delete all users
:
Press 20000 #
。
Note
:
This operation will delete all users
,
but admin card wont be deleted
4.4
Safe mode setting:
4.4.1
Normal mode
(
factory default
):
Press 3
0
#
。
4.4.2
Dead mode
:
Press 3
1
#
。
Read invalid cards 10 times continuously within 10minutes
,
the device be dead for 10 minutes
4.4.3
Alarm mode
:
Press 3
2
#
。
Read invalid cards 10times continuously within 10minutes
,
Both external alarm and built-in alarm sound.
4.5 Door open time setting
:
Press 4
0
~
99 #
。
Note
:
range“0
~
99seconds”
,
0mS equates 50mS
。
ACCESS
SECURITY
PRODUCTS
LTD