background image

PROGRAMMING

 

Programming will vary depending on access confirguration. Follow the instructions according to your access 
configuration 

 
General Programming Information – Two ways   

 

Remote Control: Please use the Infrared Remote Control to program the Reader. The infrared receiver 
head is near the LED, so when you program the reader, please direct the Remote Control to the LED 

 

User ID number: Assign a user ID to the access card in order to track it. The user ID number can be any 
number from 0-997. IMPORTANT: User IDs do not have to be proceeded with any leading zeros 
Recording of User ID is crucial. Modifications to the user require the User ID to be available   

 

Proximity Card: Any 125KHz industry standard 26 bit EM and HID Proximity card or key fob 

 
 
Sound and Light indications 

Operation Status 

Led Colour 

Buzzer 

Stand by 

Red light bright 

Enter into programming mode 

Red light shines 

One bleep 

In the programming mode 

Orange light bright 

One bleep 

Operation error 

-   

Three bleeps 

Exit from the programming mode 

Red light bright 

One bleep 

Open lock 

Green light bright 

One bleep 

Alarm ** 

Red light Shines quickly 

Bleeps 

** Please see Reset Procedure for ALARM   

 
 

Enter and Exit Program Mode Via the Remote Control 

 
 
 

 
 

 
Set New Master Code Via the Remote Control 

Programming Step 

Remote Control Operation 

1. Enter Program Mode 
2. Enter New Master Code 

* (Master Code) # 
0

New Master Code

#

Repeat New 

Master Code

# 

3. Exit Program Mode 

 
 

Set Operation Mode – Stand-alone or Wiegand (Default is stand-alone) 

Programming Step 

Remote Control Operation 

1. Enter Program Mode 
2. Stand-alone Operation 
3. Wiegand Reader Operation 

* (Master Code) # 
72 #
 is factory default for stand-alone 
73 #   

4. Exit Program Mode 

 

Programming Step 

Remote Control Operation   

1. Enter Program Mode 

* (Master Code) # 
Factory default is 123456 

2. Exit Program Mode 

ACCESS 

SECURITY 

PRODUCTS 

LTD

Summary of Contents for RD-SR2

Page 1: ...RD SR2 Proximity Card Reader with Remote Control User Manual A C C E S S S E C U R I T Y P R O D U C T S L T D ...

Page 2: ...ogrammable relay operation Pulse mode Latch mode relay operation Remote infrared programmer Master Add Master Delete cards 1000 users 998 common users 2 panic users User data can be transferred from one unit to another Wiegand 26 37 bit input output Card block enrolment Tri colour LED status display Built in light dependent resistor LDR for anti tamper Buzzer for audible or silent mode Low tempera...

Page 3: ... Contents SR2 Card Reader Infrared Remote Control Manager Cards Diode IN4004 For relay circuit protection Self Tapping Screws 3 25mm Wall Anchors Screw Driver A C C E S S S E C U R I T Y P R O D U C T S L T D ...

Page 4: ...ing cable Wire Insulation Colour Function Notes Red Power AC1 12 24 Volts AC DC Power input Black GND Ground Pink AC2 12 24 Volts AC power input Blue NO Normally open relay output Purple COM Common connection for relay output Orange NC Normally closed relay output Yellow OPEN Request to exit input REX Green Data 0 Wiegand output Data 0 White Data 1 Wiegand output Data 1 Grey Alarm output Negative ...

Page 5: ...cure power to unlock Common power supply for auto gate controller using Normally Open contact Attention Install a 1N4004 or equivalent diode across the locking device when using a common power supply to prevent any back E M F as the reader might damage 1N4004 is included in the packing A C C E S S S E C U R I T Y P R O D U C T S L T D ...

Page 6: ...ory default for stand alone 73 4 Exit Program Mode User data transfer connection 1 x power supply and 9 x SR2 units Set User Data Transfer Programming Step Remote Control Operation 1 Enter Program Mode 2 Set Transfer Data on the first SR2 For all 1000 users this will take 3 minutes Master Code 96 Within 3 minutes the green LED will shine after 1 x bleep the LED will turn red to confirm data transf...

Page 7: ...d by Red light bright Enter into programming mode Red light shines One bleep In the programming mode Orange light bright One bleep Operation error Three bleeps Exit from the programming mode Red light bright One bleep Open lock Green light bright One bleep Alarm Red light Shines quickly Bleeps Please see Reset Procedure for ALARM Enter and Exit Program Mode Via the Remote Control Set New Master Co...

Page 8: ... in a single step this takes 2 minutes 1 Present Card Repeat Step 2 for additional user cards 1 User ID Present Card The user ID is any number from 0 997 1 Input the 8 10 digit Card number 1 User ID Card Quantity The first card number Card or fob number MUST be consecutive 6 Exit Program Mode Add PIN User For Administrator for Remote Control Programming Step Remote Control Operation 1 Enter Progra...

Page 9: ...r 10 failed card attempts Default setting is OFF The strike out alarm can be set to deny access for 10 minutes after engaging or it can be set to disengage only after presenting a valid user card or Master code Programming Step Remote Control Operation 1 Enter Program Mode 2 Strike Out OFF OR 3 Strike Out ON OR 4 Strike Out ON Alarm Set alarm time Master Code 6 0 factory default 6 1 Access will be...

Page 10: ...default power off press the Exit Button or short circuit the Black GND and Yellow Open wires and then power on there will be two bleeps and the LED light will turn orange keep this condition until you hear a long bleep after 10 seconds The LED will turn red to confirm factory default is successful Reset to Factory Default to add new Mater Cards To reset to factory default power off press the Exit ...

Reviews: