User Manual for
Cellswitch 100
Page 7 of 23
INSTALLATION
Power Supply:
Wiring Techniques
Wiring for the device has been designed to be safe and easy. If the user is concerned about the
correct installation of these products or associated products, please contact a professional
electrician who is trained to the local and national standards applicable to the installation site.
Wiring Cautions
Do not lay I/O signal cables next to power cables or allow them to share the same
trunking duct. Low voltage cables should be reliably separated or insulated with regard to
high voltage cabling.
Where I/O signal lines are used over an extended distance, consideration for voltage
drop and noise interference should be made.
0V
RELA
Y COM
IN
PUT 1
S
IM C
ARD
IN
PUT 2
0V
RELA
Y N/O
RELA
Y N/C
POWER SUPPLY
+
12Vdc
RS232
12V / 500mA
C
ELLS
WITC
H 100
+12V
GSM
ANT
ENNA
General Specifications
Power supply (Regulated)
Minimum: 5Vdc 500mA
Maximum: 15Vdc 500mA
Max allowable momentary
power failure period
Less than 10ms
Average Power Consumption
at 12Vdc:
Output Off: 25mA (300mW)
Output On: 45mA (540mW)
Average Power Consumption
at 5Vdc:
Output Off: 40mA (200mW)
Output On: 45mA (540mW)
In-Rush Current
500mA