NSF61/ANSI372 Certified Lead-Free
Water Meters
with
Totalizer Only
GLF-062 to GLF-200
General Information
GLF water meters use the internationally-accepted
multi-jet principle. A gear train drives the register
totalizer dials.
Accuracy Curve
Inlet Strainer
Clean the strainer yearly, or as required, depending on
water condition. Pull out the strainer or back-flush the
meter to loosen trapped particulates.
Calibration
New meters are factory-tested to meet the AWWA
C-708 Multi-Jet Meter accuracy specification.
Suggested Meter Installation
• Thoroughly flush the service line upstream of the
meter to remove dirt and debris.
• Set the meter inline. Water meters are recommended to
be installed horizontally with the register facing upwards.
• Make sure the water flow follows the arrow cast on
the meter body.
• Slowly open any upstream valves to prevent damage
to the meter.
NSF61/ANSI372 Certified Lead-Free
Water Meters
with
Totalizer Only
GLF-062 to GLF-200
Internal Parts Replacement
All the internal parts of the meter lift out as a unit, after the
top has been unscrewed. The lens can then be removed
and internal assembly lifted out. If necessary, turn the meter
upside down and tap one end lightly on a countertop to
loosen internals. The assembly can be separated by hand.
www.accent-control.com •2101 Potshop Lane •Norristown, PA 19403 •888-265-5632
www.accent-control.com •2101 Potshop Lane •Norristown, PA 19403 •888-265-5632
1.5%
1/2”, 3/4” meters only
1”, 1 1/2” and 2” meters
Main Technical Data
US gpm
Minimum reading
US gallon
US gpm
US gpm
US gpm
062 - 5/8”
x
1/2” 075 - 5/8”
x
3/4” 100 - 3/4”
x
1”
100F - 1”
150 - 1 1/2”
200 - 2”
20
20
30
50
100
160
10
10
15
25
50
80
1
1
2
3
5
8
0.25
0.25
0.5
0.75
1.5
2
0.005
0.005
0.05
0.05
0.05
0.05
Specifications
Specifications
Certification
Meters comply with NSF/ANSI61
AnnexG, NSF/ANSI372, and conforms
with lead content requirements for
“lead-free”plumbing as defined by the
U.S. Safe Drinking Water Act effective
Jan. 1, 2014
Temperature
105˚ F (40˚ C) max
Pressure
150 psi operating max
Materials
Body/cplgs
EcoBrass*
Internals
Engineered thermoplastic
Magnet
Alnico
Accuracy
+/-1.5% of reading within Qt-Qmax
Sensor
Reed switch
Maximum Current
20 mA
Maximum Voltage
24 Vdc or Vac
Cable Length
12’ (4m) std (2000’ max run)
*EcoBrass Bronze Alloy-Lead composition is less than 0.1% by weight
3%
Flow (GPH)
Parts
5/8”x1/2” 5/8”x3/4” 3/4”x1”
1”
1 1/2”
2”
1.1 Lid/Hinge Assembly-Totalizer
A0724
A0724
A0725
A0725
A0726
A0727
2.1
Retaining Ring-Totalizer
A0728
A0728
A0729
A0729
A0730
A0731
3
Lens Gasket
A0604
A0604
A0605
A0605
A0606
A0606
4.1
Lens-Totalizer
A0003
A0003
A0003
A0003
A0003
A0003
5 O-Ring
A0644
A0644
A0645
A0645
A0646
A0646
7A Internal Assembly-Gallons
A0618
A0619
A0620
A0621
A0622
A0623
7B Internal Assembly-Cubic ft.
A0718
A0719
A0720
A0721
A0722
A0723
8 Tubular Strainer
A0016
A0016
A0018
A0018
A0020
A0022
9 Internal Strainer
A0015
A0015
A0017
A0017
A0019
A0021
10 Coupling Gasket, 2/meter
A0226
A0228
A0230
A0230
A0232
A0234
11 ,Coupling Assembly, 2/meter
A0225
A0227
A0229
A0229
A0231
A0233