Summary of Contents for 140500B

Page 1: ......

Page 2: ...al may not be used for any other purpose Any additional copies of the Manual shall be ordered from ACP No changes or modifications shall be made to the Manual without prior review and written authoriz...

Page 3: ...rapeutic Ultrasound Pulsed Shortwave Diathermy devices and advanced Therapeutic Exercise Systems Our MEGAPULSE NEUROPROBE OMNISTIM OMNISOUND OMNICYCLE OMNIVR OMNISTAND OMNIVERSA OMNISWD and SYNCHRONY...

Page 4: ...cuments Caution electrical precautions Remote Control connection CE mark of confidence compliant to MDD 93 42 EEC Connection Electrode Cable IP2X Classification against intrusion of water dust acciden...

Page 5: ...STIMULATION Optional 15 TREATMENT GUIDELINES 16 Introduction to Medium Frequency Currents 16 Electrode Application Techniques 17 SLD Infrared Pad Application Techniques 19 Treatment Preparation 19 INF...

Page 6: ...frared spectrum to provide topical heating for the purpose of elevating tissue temperature for Temporary relief of minor muscle and joint pains Minor arthritis pain and muscle spasm Relieving stiffnes...

Page 7: ...ximity less than 5 feet to an operating shortwave or microwave diathermy unit may produce instability in the device output or burns at the treatment site Lead wires and device can pick up the magnetic...

Page 8: ...s are not advised for use with OmniVersa Omnistim Systems When cleaning the device never immerse them or wash them with water See the infection control section in this manual for cleaning instructions...

Page 9: ...n Establishment of acceptable intensity levels for desensitized areas may be related to the intensity levels tolerated on normal skin in opposite or related body parts Caution should be used in the pr...

Page 10: ...on of an Estim probe Interferential Current in bipolar or quadripolar modes or Monochromatic Infrared Therapy to reduce pain and increase circulation Flexible neoprene pads deliver heat and Infrared t...

Page 11: ...selected Time remaining Carrier Frequency Bar graph for Vector and detection modes Button speeds and delay Vector selection Output current Display contrast Sweep rate and modulation selection E LEAD...

Page 12: ...output or stop the treatment START STOP also cancels the SET mode Q LED for Point Stimulation Probe output indicator R LED indicating unit is connected to line power Factory Settings The Neuroprobe 5...

Page 13: ...xtremity SLD Infrared Pad Plug it into the probe output socket Apply the SLD Infrared Pad to the treatment area Use an infection control cover over the SLD Infrared Pad and proper infection control pr...

Page 14: ...he treatment current is switched off and INFRARED THERAPY is displayed Turn off the unit by pressing the POWER button 1 5 IFC Therapy with Pad Electrodes Press the POWER button 1 5 to turn on the Neur...

Page 15: ...Note that for all IFC or INFRARED PAD protocols the treatment time is preset but may be adjusted at will during the treatment Once the treatment is completed remove the electrodes from the patient an...

Page 16: ...probe or from the output A control on the panel The stim light on the probe turns on when the unit is in stimulation mode and shuts off during detection mode The treatment is complete when all of the...

Page 17: ...r or in Quadripolar Interferential mode for patient treatment With medium frequency currents the energy of each individual pulse is low providing for stimulation of only one or two neurons Since the p...

Page 18: ...arious areas of the body Electrode placement is dependent on the etiology of the condition Monopolar Mono Polar Technique This technique may use two electrodes of different sizes however one is in the...

Page 19: ...other CERVICAL BIPOLAR PLACEMENT OF ELECTRODES IFC Quadripolar Quadri Polar Technique This technique requires the use of two output channels and four electrodes usually but not exclusively of the same...

Page 20: ...n indication of increased current density under part of or the entire electrode surface In this case immediately start to reduce the current intensity to zero remove the electrodes to inspect the surf...

Page 21: ...gelled or self adhering electrodes all increase the risk of irritation or burns and are contraindicated for use with Neuroprobe Systems Lead Wires Inspect the full length of the lead wires for signs...

Page 22: ...sure to blood body fluids containing blood semen and vaginal secretions is likely to occur Health care workers with exudating lesions or weeping dermatitis should refrain from all direct patient care...

Page 23: ...reased risk of patient cross contamination The following are the recommended practices After each use clean common contact surfaces such as control panel and lead wires with ACP germicidal wipes With...

Page 24: ...assessment tools cart handles etc 7 Set up the patient per guidelines for the procedure 8 Provide treatment as appropriate 9 Discard all disposables 10 With clean gloves remove the plastic film from...

Page 25: ...PADS NERVE BLOCK Symptomatic relief of pain from localized dermal or segmental origin 5000Hz Continuous Treatment time of 15 minutes Block pain by causing temporary nerve block via reactive depolariza...

Page 26: ...e and the red wires in the opposite phase relative to each channel All variable parameters may be altered during operation I SENSORY MOTOR PROBE TREATMENT PROTOCOLS The Sensory Motor protocols contain...

Page 27: ...onal electrotherapy approaches Its primary application is in the reduction of pain and in the stimulation of increased blood flow in the deeper tissues and muscles The following pads programs are avai...

Page 28: ...0 seconds 0 20 Seconds Beat Sweep Rate Scan Time Modulation ON ON or OFF Vector Auto Intensity 0 0 20 Treatment time 30 minutes 0 99 Minutes Waveform Burst Alternating Current Output 0 mA 0 99 mA PADS...

Page 29: ...y be varied during operation and saved by the user The following program is available in Noxious Probe mode PROBE NOXIOUS Sensory Noxious Waveform PARAMETER DEFAULT VALUES RANGE OF USER ADJUSTABLE VAL...

Page 30: ...USER ADJUSTABLE VALUES Carrier frequency 5 0 KHz Stim time 60 Seconds 0 999 Seconds Waveform Alternating Current Output 0 mA 0 2 25 mA II NERVE BLOCK PADS AND SLD INFRARED PAD PROTOCOL The Nerve Block...

Page 31: ...if the lead wire passes the test LED will be red if the lead wires are faulty and need to be replaced see Figure 7 below Remove electrode s and replace if necessary Adjust output up or down as necess...

Page 32: ...d INSPECT POWER SUPPLY OPERATION 1 Connect the power cord to the power supply and to a power outlet 2 Connect the power supply cable to the stimulator unit Figure 4 Figure 4 3 Press the power supply s...

Page 33: ...ceptacle labeled LEAD WIRE TESTER When the POWER is on green LED will turn on if the lead wire passes the test LED will be red if the lead wires are faulty and need to be replaced Figure 7 Service Cen...

Page 34: ...S RESERVED For repair or service of ACP Products and accessories please call 800 350 1100 and follow the prompts Normal hours of operation are 6 00am to 5 00pm Pacific Standard Time After hours please...

Page 35: ...r Scans amplitude of channel A from 0 maximum every 10 seconds relative to channel B which varies concurrently out of phase Slow 90 Scans amplitude of channel A from 0 maximum every 60 seconds relativ...

Page 36: ...conductivity PATIENT SAFETY SYSTEMS Activation By patient safety hand control which shuts down output Output modality may not be changed during operation Output levels are reset to zero at the start a...

Page 37: ...ptional probe IFC and SLD Infrared Pad treatments Shipping Weight 4 lbs 1 8 kg ITEM ITEM NO DESCRIPTION 48758 Lead Wire Blue Green Coded plug in 7 214cm 080 tip pin stereo plug 55055 Grounding Pad 3x4...

Page 38: ...stim Electrodes 4ea pkg 10pkg bx 61227 2x4 Multi use E stim Electrodes 4ea pkg 10pkg bx 26854 3x5 Multi use E stim Electrode 2ea pkg 10pkg bx SINGLE USE ELECTRODES 28303 2x2 Single use E stim Electrod...

Page 39: ...trol of Touch Operatory Surfaces 4 x 6 Clear Perforated Sheets 1200 sheets roll 50593 Barrier Film for Infection Control of Infrared Therapy Pads 12 x 14 Perforated Sheets 800 sheets roll 63574 Barrie...

Page 40: ...oid if any of the following have occurred 1 The product contains repairs or replacement parts not furnished by ACP 2 The product is damaged resulting from misuse or negligence 3 The product has been t...

Page 41: ...ed repair is deemed to be under warranty ACP is not responsible for any loss or damage to the Equipment prior to receipt at the ACP Service Center Equipment returned for warranty service must be shipp...