Accademia Laboratory Niko 1300M User Manual Download Page 4

 

1. Read these instructions. 

2. Keep these instructions. 

3. Heed all warnings. 

4. Follow all instructions. 

5. Do not use this apparatus near water. 

6. Clean only with a dry cloth. 

7. Do not block any ventilation openings. Install in accordance with the 

manufacturer’s instructions. 

8. Do not install near any heat sources such as radiators, heat registers, 

stoves, or other apparatus (including amplifiers) that produce heat. 

9. Do  not  defeat  the  safety  purpose  of  the  polarized  or  grounding-type 

plug. A polarized plug has two blades with one wider than the other. A 

grounding-type plug has two blades and a third grounding prong. The 

wide blade or

the third prong is provided for your safety. If the provided plug does 

not  t  into  your  outlet,  consult  an  electrician  for  replacement  of  the 

obsolete outlet. 

10. Protect the power cord from being walked on or pinched, particularly 

at plugs, convenience receptacles, and the point where they exit from 

the apparatus. 

11. Only use attachments/accessories specifed by the manufacturer. 

12. Use  only with  a  cart, stand, tripod, bracket, or  table  specifed  by the 

manufacturer, or sold with the apparatus. When a

cart is used, use caution when moving the cart/apparatus combination 

to avoid injury from tip-over. 

13. Unplug  this  apparatus  during  lightning  storms  or  when  unused  for 

long periods of time. 

14. Refer all servicing to qualified service personnel. Servicing is required 

when  the  apparatus  has  been  damaged  in  any  way,  such  as  power-

supply  cord  or  plug  is  damaged,  liquid  has  been  spilled  or  objects 

have  fallen  into  the  apparatus,  the  apparatus  has  been  exposed  to 

rain or moisture, does not operate normally, or has been dropped. 

15. Use the mains plug to disconnect the apparatus from the mains. 

16. WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, 

DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE. 

17. DO  NOT  EXPOSE  THIS  EQUIPMENT  TO  DRIPPING  OR  SPASHING 

AND ENSURE THAT NO OBJECTS FILLED WITH LIQUIDS, SUCH AS 

VASES, ARE PLACED ON THE EQUIPMENT. 

18. THE MAINS PLUG OF THE POWER SUPPLY CORD SHALL REMAIN 

READILY OPERABLE.

TO PREVENT ELECTRIC SHOCK DO NOT REMOVE TOP OR BOTTOM 
COVERS. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING 
TO QUALIFIED SERVICE PERSONNEL. 

TO COMPLETELY DISCONNECT THIS EQUIPMENT FROM THE AC 
MAINS, DISCONNECT THE POWER SUPPLY CORD PLUG FROM THE 
AC RECEPTACLE. THE MAINS PLUG OF THE POWER SUPPLY CORD 
SHALL REMAIN READILY OPERABLE. 

WATCH FOR THESE SYMBOLS:  

The lightning bolt triangle is used to alert the user to the risk of electric 
shock. 

The exclamation point triangle is used to alert the user to important 
operating or maintenance instructions. 

MAGNETIC FIELD  

CAUTION! Do not locate sensitive high-gain equipment such as pre-
amplifiers directly above or below the unit. Because this amplifier has a 
high power density, it has a strong magnetic eld which can induce hum 
into unshielded devices that are located nearby. The eld is strongest just 
above and below the unit.

www.accademialab.com

 of 

4

15

Rel: 1/8/2018 V1 RevA

SAFETY PRECAUTION

Summary of Contents for Niko 1300M

Page 1: ...USER MANUAL NIKO1300M MONO AMPLIFIER 1...

Page 2: ......

Page 3: ...www accademialab com of 3 15 Rel 1 8 2018 V1 RevA AccademiaLab Srl Manual release 1 8 2018 Accademia Laboratory Italy Version 1 rev A info accademialab com Language English www accademialab com...

Page 4: ...when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or...

Page 5: ...8 INPUT SELECTOR SWITCH 8 INPUT GAIN SELECTOR 8 LED LOGO 9 LED STATUS INDICATOR 9 CONNECTIONS 10 POWER PANEL 10 POWER PLUG 10 MAIN POWER SWITCH 10 USB 10 TRIGGER JACK 10 INPUT PANEL 11 UNBALANCED RCA...

Page 6: ...damage during shipment Please verify the shipment for completeness refer to the table below If there is any sign of damage or incompleteness to the items listed in the table below please contact your...

Page 7: ...ated analog power supplies use two separate custom design 1000VA toroidal transformers Two capacitor filtering banks provide a massive 100 000 F running at 85V with the capability to store up to 300jo...

Page 8: ...ed blue the Niko1300M is not isolated from that mains power the amplification stages is power off Only in this phase is safe to operate with the input and output connection ON status led green the Nik...

Page 9: ...ront panel the colors of the led detect 4 different state led status If the amplifier is in protection mode just turn it completely off and reboot the system LED COLOR CODIFICATION BLUE The amplifier...

Page 10: ...f the circuit breaker before wait 10 second from the standby ON the Niko1300M check the system before entering the standby mode 2 second Usb update This UPDATE USB port fig 3 1A is only for update and...

Page 11: ...t selector switch The gain selector is an input attenuator View fig 4 2 for details www accademialab com of 11 15 Rel 1 8 2018 V1 RevA CONNECTIONS GAIN ATTENUATION 0 0db 1 3db 2 6db 3 12db 4 18db 5 in...

Page 12: ...wer cables www accademialab com of 12 15 Rel 1 8 2018 V1 RevA CONNECTIONS POWER PANEL NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL TO PREVENT THE RISK OF ELECTRIC SHOCK DO N...

Page 13: ...ng Neutrik NL4 Binding Post PIN CONNECTION 1 POSITIVE 1 NEGATIVE 2 NOT CONNECTED 2 NOT CONNECTED PIN CONNECTION RED POSITIVE BLACK NEGATIVE GREEN GROUND www accademialab com of 13 15 Rel 1 8 2018 V1 R...

Page 14: ...UNBAL IN XLR BAL IN CH RIGHT TWO BLOCKS ONE CHASSIS A M P L I F I E R DESIGNED ENGINEERED AND HANDCRAFTED IN ITALY WITH COMPONENTS OF REFERENCE INPUTS PANEL CH LEFT RCA UNBAL IN XLR BAL IN t e c h n...

Page 15: ...www accademialab com of 15 15 Rel 1 8 2018 V1 RevA...

Reviews: