43
Technical Information
Warning: Be sure to wait a minimum of 20 minutes
after turning off all power supplies and discharge the
refrigerant completely before removal.
Step
Procedure
1. Remove big handle and wire
connection cover
Before disassembly, remove the screws
fixing big handle and right side plate to
remove the big handle.
Remove the screws fixing wire connection
cover and right side plate to remove the wire
connection cover.
AWHD(18)ND3EO AWHD(18)ND3FO AWHD(18)ND3GO
11. REMOVAL PROCEDURE
!
48
Installation and Maintenance
Service Manual
11. Removal Procedure
Warning: Be sure to wait for a minimum of 20 minutes after turning off all
power supplies and discharge the refrigerant completely before removal.
Steps
Procedure
Remove the screws fixing big handle and right side
plate to remove the big handle.
1.Remove big handle and wire connection cover
Before disassembly
Remove the screws fixing wire connection cover
and right side plate to remove the wire connection
cover.
big handle
wire connection cover
WHD(18)ND3EO GWHD(18)ND3FO GWHD(18)ND3GO