PROGRAMMING
CONTROLLER MODES
Pressing the mode button will cycle through the controller’s available programming modes: OFF, ON,
AUTO (4 triggers), TIMER TO ON, TIMER TO OFF, CYCLE (On and Off), and SCHEDULE (On and
Off).
ON MODE
Your fan will actively run at the speed set,
regardless of the probe's reading. The ON mode
also serves as the maximum speed setting the
other modes will run in.
OFF MODE
Your fan will not run while in this mode. However,
the fan speed set while in this mode establishes
the minimum speed in the other modes. When the
fan is triggered to turn OFF in all other modes, it
will instead run at the speed set here.
AUTO MODE (HIGH TEMPERATURE TRIGGER)
Pressing the up or down button sets the high
temperature trigger. The fans will activate if the
probe’s reading meets or exceeds this threshold.
Once triggered, the fan will gradually ramp up to the
speed set in ON mode. If the probe’s reading falls
below this trigger point, the fans will gradually slow
down to a stop or at the speed set in OFF mode.
You may set this trigger below the low temperature
trigger to create a specific range in which the fan is
active.
Note that this trigger can activate as long
as you are in AUTO Mode, even if you are
viewing a different trigger within AUTO Mode.
If there is a speed set in OFF Mode other
than zero, the fans will run at that speed when
triggered to turn off.