PROGRAMMING
AIRCOM T8 T9 T10
QUICK START
Press the MODE button until you are on AUTO mode. This mode works like a thermostat. Then
press the up and down triangle buttons to change the SETTING temperature on the screen. The
PROBE temperature is what the thermal probe is measuring. When the PROBE temperature
exceeds the SETTING temperature, the fans will start running.
ON MODE
In this mode, the fans will run non-stop regardless of
temperature. Pressing the up and down buttons while in this
mode will change the speed of the fan. Whichever speed is
designated in this mode will also be the speed used in AUTO
Mode and the max speed of the fans in SMART Mode.
AUTO MODE
This is the thermostat setting where the fans will start
running when the PROBE temperature reaches or surpasses
the SETTING temperature. The SETTING temperature can
be designated by pressing the up and down buttons while
in this mode. Once the fans start running, the PROBE
temperature would need to fall at least 4° F below the
SETTING temp for the fans to stop running. This variation
buffer can be changed to 2° F, see page 18 for more
information.