Page 3: ...roduct quality and friendly customer service If you have any questions or suggestions please don t hesitate to contact us Visit www acinfinity com and click contact for our contact information EMAIL support acinfinity com WEB www acinfinity com LOCATION Los Angeles CA ...

Page 4: ...M S7 AIRCOM S8 AIRCOM S9 AIRCOM S10 AIRCOM T8 AIRCOM T9 AIRCOM T10 MODEL AI ACS6 AI ACS7 AI ACS8 AI ACS9 AC ACS10 AI ACT8 AI ACT9 AC ACT10 UPC A 854759004624 854759004631 854759004648 854759004655 819137020320 854759004662 854759004679 819137020313 ...

Page 5: ...Index Product Requirements Key Features Product Contents Product Setup Programming S6 S7 S8 S9 S10 Programming T8 T9 T10 Other AC Infinity Products Warranty Page 5 Page 6 Page 8 Page 9 Page 10 Page 12 Page 14 Page 20 Page 21 ...

Page 6: ...NCLOSED CABINETS The cooling system is not compatible with fully enclosed cabinets Air must be able to travel in and out of the cabinet Please make sure that your cabinet has ventilation holes or is open at the front or back REAR EXHAUST MODELS For models containing blowers AIRCOM S6 S8 and T8 the cabinet s ventilation holes should be at the rear The hot air that the cooling system is exhausting s...

Page 7: ...em s vents OPERATION LIMITATIONS The fan system has an operating temperature rating of 32 F to 140 F and a humidity rating of 35 to 85 RH Please make sure that the system s environment does not exceed these parameters COMPONENT VENTS The cooling system is designed to be placed on top of AV components to draw out hot air upwards or at the rear The system works more effectively if the AV component h...

Page 8: ... to maximize airflow CFM to noise dBA ratio Contains long life dual ball bearings EXPANDABLE PORTS AIRPLATE and MULTIFAN fans can be plugged into the unit to share temperature and fan speed settings T SERIES CONTROLLER LCD display enables active temperature monitoring thermal control speed control and SMART energy mode S SERIES CONTROLLER Features fan speed control and a pre set temperature trigge...

Page 9: ...RCOM S8 AIRCOM S9 AIRCOM S10 AIRCOM T8 AIRCOM T9 AIRCOM T10 AI ACS6 AI ACS7 AI ACS8 AI ACS9 AC ACS10 AI ACT8 AI ACT9 AC ACT10 POWER ADAPTER x1 POWER ADAPTER x1 POWER ADAPTER x1 COOLING FAN SYSTEM x1 COOLING FAN SYSTEM x1 COOLING FAN SYSTEM x1 ...

Page 10: ... PRODUCT SETUP STEP 1 Insert the AC plug of your power adapter into a power outlet STEP 2 Plug the male connector of the adapter into the female connector located on the backside of the cooling fan system ...

Page 11: ...ponent STEP 4 Set up the cooling fan system s temperature and speed settings on the control module Refer below to see the model and instructions to follow Please refer to Page 12 for instructions Please refer to Page 14 for instructions AIRCOM S6 S7 S8 S9 S10 AIRCOM T8 T9 T10 ...

Page 12: ...n AUTO Mode FAN SPEED LIGHT Indicates fan speed and also the speed settings of AUTO and SMART Mode ON MODE LIGHT This white light indicates if the system is running in ON Mode SPEED CONTROL BUTTON Pressing this button changes the speed settings while the fans are running in ON AUTO and SMART Mode FAN SPEED LIGHT OPTIONS The fan speed light displays the current speed of the fan However the light ca...

Page 13: ... the orange and white light will be visible to indicate if the system is running in SMART Mode In this mode the fans will change speed depending on the measured temperature For every 2 F increment that the temperature is below 88 F the speed of the fans will decrease by one level OFF MODE In this mode the white and orange light will not be visible and the fans will not run regardless of temperatur...

Page 14: ...htness of the display Four settings are available 5 ALARM TEMP Shows the temperature that you set the fan s alarm system to trigger 9 ALERT ICONS Flashes to indicate if check fan alert or display lock is being triggered 6 PROBE TEMP Actively shows current temperature that the probe is measuring 2 UP DOWN BUTTON The up and down buttons changes the setting temp alarm temp display brightness or the s...

Page 15: ... up and down buttons while in this mode will change the speed of the fan Whichever speed is designated in this mode will also be the speed used in AUTO Mode and the max speed of the fans in SMART Mode AUTO MODE This is the thermostat setting where the fans will start running when the PROBE temperature reaches or surpasses the SETTING temperature The SETTING temperature can be designated by pressin...

Page 16: ...t setting SMART MODE This is the energy saving mode where the fans will change speed depending on the temperature The SETTING temperature can be designated by pressing the up and down triangle buttons while in this mode For every 4 F increment that the PROBE temperature is below the SETTING temperature the speed of the fans will decrease by one level This increment can be changed to 2 F please see...

Page 17: ...m is triggered the fan will run at max speed regardless of mode and will make an audible beep every three seconds This will keep occurring until the temperature drops below the ALARM temp or if any buttons are pressed The alarm can be disabled to not trigger by pressing the up triangle button until the temperature is at 140 F then pressing the up button once more to show OF FAHRENHEIT OR CELSIUS T...

Page 18: ... 4 Fahrenheit or 2 Celsius hold the MODE button and UP button together for three seconds CONTROLLER LOCK Holding the MODE button for three or more seconds will lock the controller The controller will still work as programmed However pressing any buttons will not have an effect and will cause the screen lock icon to flash This option was designed to prevent your controller settings from being chang...

Page 19: ...sible issues If the fan is rotating it may just be static pressure resistance and operating as intended If the fan is not rotating please see the warranty page for replacement information ALARM ALERT The alarm alert icon will flash when the probe temperature reaches or exceeds the alarm temperature you have set Please see page 17 for more information on setting up the alarm DISPLAY LOCK ALERT This...

Page 20: ...mically It features an inline speed controller and can be powered by an USB port The fans can also be powered through a power outlet with a Boost Speed Adapter sold separately PRODUCT AIRPLATE S1 AIRPLATE S3 AIRPLATE S5 AIRPLATE S7 AIRPLATE S9 PRODUCT MULTIFAN S1 MULTIFAN S3 MULTIFAN S4 MULTIFAN S5 MULTIFAN S7 MODEL AI CFS80BA AI CFS120BA AI CFD80BA AI CFD120BA AI APS9 MODEL AI MPF80A AI MPF120A A...

Page 21: ...two years from the date of purchase If your product becomes defective during that period AC Infinity will replace your product with a new one or issue you a full refund The warranty program does not cover abuse or misuse This includes physical damage submersion of the product in water incorrect Installation such as wrong voltage input and misuse for any reason other than intended purposes AC Infin...