background image

14

POWERING AND SETUP

CLOUDFORGE T3

STEP 1

Plug the sensor probe into the 3.5mm jack 
located at the rear side.

Route the probe head to spot areas as needed.

Summary of Contents for AC-CFT3

Page 1: ...1 USER MANUAL CLOUDFORGE ENVIRONMENTAL HUMIDIFIER ...

Page 2: ......

Page 3: ...roduct quality and friendly customer service If you have any questions or suggestions please don t hesitate to contact us Visit www acinfinity com and click contact for our contact information EMAIL support acinfinity com WEB www acinfinity com LOCATION Los Angeles CA ...

Page 4: ...4 MANUAL CODE CF2207X1 MODEL AC CFT3 AC CFT5 AC CFT7 AC CFT9 PRODUCT CLOUDFORGE T3 CLOUDFORGE T5 CLOUDFORGE T7 CLOUDFORGE T9 UPC A 819137023611 819137023635 819137023628 819137023642 ...

Page 5: ...ontents Installation Powering and Setup Universal Infinity SystemTM Connecting to UIS Controllers Cleaning Programming Other Settings Other AC Infinity Products Warranty Page 5 Page 6 Page 7 Page 8 Page 9 Page 14 Page 18 Page 19 Page 20 Page 22 Page 26 Page 27 Page 28 ...

Page 6: ...e or chemical laden atmospheres Do not cover any power cords with rugs or other fabric materials Safety precautions should be exercised during the installation operation and maintenance of this product Do not block or tamper with this product in any manner while it is in operation as it may cause electric shock fire or damage to this product Do not depend on the on off programming as the sole mean...

Page 7: ...R Onboard controller with LED touch interface featuring humidity balance programming Pair with UIS controllers to access intelligent programming and app control with advance automation and data charts PRECISION DETECTION Swiss made thermal alloy sensor made of SAE grade 316 steel detects humidity changes and provides up to the minute readings Extension cord enables detection in spot areas and conv...

Page 8: ... BRUSH x1 UIS EXTENSION CORD M M x1 HOOK AND LOOP TIE x1 PRODUCT CONTENTS 4 5L HUMIDIFIER x1 FLEXIBLE HOSE x1 CLOUDFORGE T7 15L HUMIDIFIER x1 ALL MODELS SENSOR PROBE x1 PIPE BASE x1 ELBOW NOZZLE x1 5 WAY NOZZLE x1 ELASTIC BANDS x4 PVC PIPE x1 ...

Page 9: ...r into the tank You may detach the tank to fill it with water We recommend using distilled water to reduce the amount of mineral build up B NOTE Do NOT pour water into the central pipe This will prevent your humidifier from functioning properly A ...

Page 10: ...10 INSTALLATION CLOUDFORGE T3 STEP 2 You may swap the directional flow cap with the included flexible hose for extended targeted flow A B ...

Page 11: ...r into the tank You may detach the tank to fill it with water We recommend using distilled water to reduce the amount of mineral build up B A NOTE Do NOT pour water into the central pipe This will prevent your humidifier from functioning properly ...

Page 12: ...g with the included base Attach the pipe onto the base followed by your choice of nozzle A Elbow nozzle for unidirectional flow B 5 way nozzle for omnidirectional flow A B Make sure the elbow nozzle is placed over the pipe with the interior ridge facing the ground ...

Page 13: ...13 INSTALLATION CLOUDFORGE T7 STEP 3 You may use your own PVC pipes to extend the reach of your humidifier Line the pipe with the included elastic band and attach it to the base or elbow nozzle A B ...

Page 14: ...14 POWERING AND SETUP CLOUDFORGE T3 STEP 1 Plug the sensor probe into the 3 5mm jack located at the rear side Route the probe head to spot areas as needed ...

Page 15: ...ND SETUP CLOUDFORGE T3 STEP 2 You may plug the included UIS extension cord into the rear side port to connect your humidifier to your UIS controller STEP 3 Plug the humidifier s power plug into an outlet to power it ...

Page 16: ...TUP CLOUDFORGE T7 STEP 1 Plug the sensor probe into the 3 5mm jack located below the display screen Route the probe head to spot areas as needed You may also use the included probe mount to cable manage the corded probe ...

Page 17: ...D SETUP CLOUDFORGE T7 STEP 3 Plug the humidifier s power plug into an outlet to power it STEP 2 You may plug the included UIS extension cord into the front side port to connect your humidifier to your UIS controller ...

Page 18: ...y connect with various grow equipment such as inline fans clip on fans and grow lights Advance UIS controllers can provide each connected UIS device with their own automated programming like temperature humidity cycles schedules and dynamic levels while also pairing with the AC Infinity app Central controllers and grow devices will be sold separately and may still be in development at the time of ...

Page 19: ...TROLLER 69 unit will override all onboard settings and assume control parameters must be adjusted on CONTROLLER 69 when connected in this manner The humidifier s touch functions will also be deactivated CLOUDFORGE humidifiers can connect with CONTROLLER 69 sold separately as part of an integrated system using the included UIS extension cord ...

Page 20: ...he base STEP 2 Pour out any water sitting in the base Pour two cups of distilled water and one tablespoon of vinegar into the base Let it sit for five minutes 2 Change water reservoir at least once every 4 days Clean and maintain the unit at least once per week VINEGAR ...

Page 21: ...21 CLEANING STEP 3 Use the included brush to remove any build up from the nebulizer s STEP 4 Pour out the vinegar water mixture and wipe the base dry Replace the tank to finish ...

Page 22: ...ur mark intervals to show when your humidifier will turn off 4 TIMER BUTTON Sets a countdown timer to turn your humidifier off ranging between 1 and 12 hours in 1 hour increments 3 AUTO BUTTON Sets the low humidity trigger ranging between 35 and 95 in 5 increments 2 HUMIDITY BUTTON Cycles through the humidifier s misting levels between 0 and 4 8 ALERT ICONS Displays alerts and statuses of the onbo...

Page 23: ...e level to zero or the device will turn off when it s triggered ON POWER MODE Turns your humidifier ON or OFF The LCD screen will not display while it is off You must power your humidifier on before adjusting settings in other modes HUMIDIFIER MODES Tap one of the following buttons on the controller to access that button s programming mode POWER MIST AUTO low humidity trigger and TIMER to OFF ...

Page 24: ...ill stop emitting mist Leaving the AUTO mode while it is active will pause it until you return to this mode TIMER MODE TO OFF Tapping the timer button sets a countdown time Your humidifier will run at the level set in MIST mode until the countdown ends The countdown will begin if no buttons are tapped for 3 seconds The time left on the countdown is displayed as a dial inside of the current mist le...

Page 25: ...Displays when the tank s water level is low Your humidifier s power mist auto and timer buttons will flash and will pause programming until the tank is replenished AUTO MODE ALERT Flashes whenever the AUTO mode trigger activates your humidifier DISPLAY LOCK ALERT Displays when you lock the controller The icon will flash and beep if you attempt to adjust your humidifier while it is still locked ...

Page 26: ...ower button to turn the display off Tapping it again will turn the display back on Programs will still run in the background while the LCD screen is off PRESS RESET TO OFF DEFAULT Holding the mist auto or timer button for 3 seconds will reset the value of your current mode to Default Pressing either the mist auto or timer button will return to the previous value FACTORY RESET Holding the auto and ...

Page 27: ...M series is a line of smart thermo hygrometers designed to accurately detect and measure your space s temperature and relative humidity Features a bright backlit screen and desktop wall or magnetic mounting options to place and display anywhere Select models include a corded Swiss made sensor probe by Sensirion AG for spot detection CONTROLLER 69 The CONTROLLER 69 is the centerpiece of the Univers...

Page 28: ...he date of purchase The program will expire two years from the date of purchase If your product becomes defective during that period AC Infinity will replace your product with a new one or issue you a full refund The warranty program does not cover abuse or misuse This includes physical damage submersion of the product in water incorrect Installation such as wrong voltage input and misuse for any ...

Page 29: ... part of the materials including graphics or logos available in this booklet may be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form in whole or in part without specific permission from AC Infinity Inc ...

Page 30: ......

Page 31: ......

Page 32: ...www acinfinity com ...

Reviews: