PROCEDURE
Ex-factory setting pressure value
is aproximately 50. This value
should never be more than 56.
Press the security pin to replace
the insert. When replacing an
insert, remove the battery from
the tool to prevent any accidents.
Place the insert corresponding to
the diameter of the fitting and se
-
cure it with the security pin.
Make sure that the inserts close
completely and there is no space
between them when pressing the
fitting.
If there is any space between the
inserts, rotate the rear nut of the
tool as shown in the picture.
The crimping head can be tur-
ned by 90 degrees.
When the green light is blinking,
it is charging; when the two lights
are on, it means that charging is
completed.