PROCEDURE

Ex-factory setting pressure value 

is aproximately 50. This value 

should never be more than 56.

Press the security pin to replace 

the insert. When replacing an 

insert, remove the battery from 

the tool to prevent any accidents.

Place the insert corresponding to 

the diameter of the fitting and se

-

cure it with the security pin.

Make sure that the inserts close 

completely and there is no space 

between them when pressing the 

fitting.

If there is any space between the 

inserts, rotate the rear nut of the 

tool as shown in the picture.

The crimping head can be tur-

ned by 90 degrees.

When the green light is blinking, 

it is charging; when the two lights 

are on, it means that charging is 

completed.