34
COMMUNICATION
CAMERA ID
001
BAUD RATE
9600
PARITY
NONE
DEFAULT
RETURN>
Function
Description
CAMERA ID
Setting for the RS-485 camera ID (ID 0 is reserved for the control
unit)
BAUD RATE
Setting for the baud rate of the RS-485 communication interface.
PARITY
Setting for the parity of the communication interface.
DEFAULT
Restores all values in the sub-menu to the factory settings
RETURN
Back to main menu
Function
Description
BLOCK DISP
ON: When the video image content changes, the corresponding
points are marked with square blocks.
OFF: Block display is deactivated
DETECT SENSE
Sensitivity of the image change detection A higher value
increases the sensitivity
DURATION
Set delay time for the zoom factor (5, 10, 15, 20, 30 seconds, 1, 2,
3,4 or 5 minutes)
ALARM OUT
ON: Switching output is activated for successful motion detection.
OFF: Switching output is not activated for successful motion
detection.
ZOOM RATIO
Zoom factor which is set by the camera automatically for
successful motion detection.
DEFAULT
Restores all values in the sub-menu to the factory settings
RETURN
Back to main menu