68
68 69
|
15. Technical data
Electromagnetic compatibility
EMC – immunity
Complies with EN 50130-4
Electromagnetic compatibility
EMC – interference
Complies with EN 61000-6-3
Electrical safety
Complies with EN60950-1
Power supply
Type of power supply
Type A (EN 50131-1 Section 9 and EN 50131-6 Section 4.1)
Secvest has an integrated power supply unit (Type A). This power supply
unit supplies different internal voltages to the circuit board to supply
power to the circuitry.
This power supply unit supplies 13.8 V with a maximum of 700 mA
at the 0 V/12 V AUX output.
Normal voltage/frequency
110 V/230 V AC, 50/60 Hz, (85-265 V AC, 50/60 Hz)
13.8 V DC (13.0–14.5 V DC)
Power consumption, maximum
I AC MAX:
430mA rms @ 85VAC
190mA rms @ 230VAC
170mA rms @ 265VAC
Power consumption, nominal
6.9 W
6.9 W x 24 x 365 = 60 kWh per year
55mA rms @ 230VAC
specified with 200 mA aux load and fully charged batteries
300 mA @ 13.8 V
External DC input fault triggered at
12.5 V
OK at 12.7 V
External PSU
13.0–14.5 V DC, at least 1.7 A
Power consumption, typical
Alarm panel standby: 100 mA
Backlighting off
Backlighting:
High: 100 mA
Medium: 40 mA
Low: 15 mA
Internal siren sounding alarm at maximum volume: 70 mA
GSM standby:15 mA
GSM in use: 140 mA
Battery charging current per battery: 220 mA