![Abus RS-485 Installation Manual Download Page 8](http://html.mh-extra.com/html/abus/rs-485/rs-485_installation-manual_454078008.webp)
8
Inputs: 1x RS232, 2x RS485
(All inputs can simultaneously be in standby mode, but only one controller can transmit at any
one time.)
Outputs: 4x RS485; up to 1200m cable (twisted pair) can be connected to each output.
Overvoltage protection on each channel
Isolated inputs and outputs
Possibility of cascading with other TV8473
The equipment distributes the serial data to all four outputs simultaneously.
Technical data
Data input
2 x RS485 (screw clamps) 1x RS232 port
Data output
4 x RS485 (screw clamps)
Voltage supply
12V DC
Power consumption
350mA
Ambient operating temperature
0 °C to 45 °C
Ambient operating humidity
Up to 95% relative humidity
Dimensions (LxBxD)
133 x 76 x 44 mm
Weight 425g
Casing Metal,
black