Abus RM20 User Manual Download Page 6

– 16 –

– 17 –

As a minimum requirement 

RM

smoke alarms should be installed in 
all bedrooms, children’s rooms and 
corridors that function as escape 
routes, only in the middle of the 
ceiling (no wall mounting).

Choose the highest point to install 
the unit, ensuring that it is posi- 
tioned at least 50 cm away from 
surrounding walls, furniture and 
lamps. To provide optimum protec- 
tion 

RM

 for your home, install units 

in all the other rooms and in the 
stairwells. The unit is also suitable 
for use in the kitchen (the most com- 
mon location for household fires).

In most cases, there is no need to 
install a smoke alarm in washrooms 
(bathrooms, toilets, etc.) such rooms 
represent a low fire risk.

Please observe the diagrams included 
in these instructions.

The unit can detect a fire early on 
on the basis of the rising smoke and 
the connected temperature increase 

in the temperature in the room. 
In the event of fire, a loud alarm tone 
sounds as a warning. If you are sure 
that there is no genuine need to evac- 
uate the building, you can temporar- 
ily deactivate the alarm tone (for roughly 
10 minutes) or disable the tone before 
it is activated by gently pressing the 
unit’s test and stop button (IV).  
In such a case, it is advisable to venti- 
late the affected rooms well to prevent 
the alarm from being activated a 
second time.

BATTERY FAULT WARNING

If a single brief signalling tone (“beep”) 
sounds roughly every 90 seconds, the 
battery capacity is low. If a double 
brief signalling tone (“beep-beep”) 
sounds roughly every 90 seconds, the 
unit is no longer able to filter out 
imperfections in the detection optics. 
Both signalling tones can be tempo- 
rarily deactivated (for 24 hours) by 
pressing the test and stop button (IV).
If the smoke alarm is emitting either
of the above-described signalling 

•  Heat alarm tone: single beep, once 
  a second
•  Smoke alarm tone: double beep,  
  once a second

CHooSING A LoCATIoN

390371_MoAnltg RM 20_D_GB_F_NL_I_11.2012.indd   17

14.11.12   13:16

Summary of Contents for RM20

Page 1: ...vice with heat alarm function GB Consignes d utilisation et d installation D tecteur d alarme de fum e avec signal d avertissement de chaleur F Gebruikers en installatiehandleiding Rookmelder met hitt...

Page 2: ...RM20 Smoke alarm device with heat alarm funktion User manual Smoke alarm device with heat alarm function GB MoAnltg RM 20_D_GB_F_NL_I_11 2012 indd 13 14 11 12...

Page 3: ...ly 18 Adhesive Mounting 18 Mounting by Drilling 18 General Safety Guidelines 19 Inspection and Maintenance 20 Equipment life 21 Possible Causes of a Fault Alarm 21 Warranty 22 Intended Use 22 CE Confo...

Page 4: ...as been developed and manufactured with the utmost care so that you can be made aware of a fire risk in your home in due time To achieve optimum unit performance please read through and observe these...

Page 5: ...en you press the test and stop button Fig 1 IV to verify that the unit is operating correctly Function The heat alarm function is activated under the following conditions When the temperature is over...

Page 6: ...the connected temperature increase in the temperature in the room In the event of fire a loud alarm tone sounds as a warning If you are sure that there is no genuine need to evac uate the building yo...

Page 7: ...that the unit is held securely Take care not to fasten the tones the unit will continue to function for a maximum of 60 days and needs to be replaced before this 60 day period has expired INSTALLATIO...

Page 8: ...em Any form of tampering with the unit s interior will result in the loss of any existing warranty and make it impossible for the unit to be implemented in accordance with its intended use Never open...

Page 9: ...low or if the detec tion optics have become so full of imperfections that readjustment is no longer possible This gives you sufficient time to replace the smoke alarm with a new unit Please ensure th...

Page 10: ...mity to the unit An alarm can only be activated by cigarette smoke if the smoke enters the unit directly or in very high concentrations The unit should be protected from the abovemen tioned environmen...

Page 11: ...n compliance with this operating and installation instructions document If a warranty claim is asserted the smoke alarm must be returned with the original receipt with date of purchase and a brief wri...

Page 12: ...ISIONS THE WARRANTIES ARE RESTRICTED TO THE DURATION OF THESE WARRANTIES LIMITATION OF LIABILITY YOUR RIGHTS ARE RESTRICTED TO THE REPAIR OR THE REPLACEMENT OF THE PRODUCT AS DELIVERED ABUS ASSUMES NO...

Page 13: ...24 Notes MoAnltg RM 20_D_GB_F_NL_I_11 2012 indd 24 14 11 12...

Reviews: