1.  product launch 

1.1.  Scope of delivery 

  ABUS by Sensative Z-Wave door/window contact 

  2 magnets (rectangular, round) 

  cleaning cloth 

  Quick guide & safety instructions 

  DSK card 

 

1.2.  device features 

 

    

 

 
 

No  designation 

comment 

LED Indicator 

Status display for various processes (inclusion, exclusion, reset, 
error) 

Opening contact or 
square magnet  

Detects Open, Closed 

Configuration contact 
or round magnet  

Manual triggering of wake-up command, inclusion, exclusion and 
reset 

 
 

1.3.  Functionalities 

The PLMK10000 is designed for use in alarm and home automation systems using the Z-Wave radio 
standard. The device includes the following sensors: 

  Hall sensor for detection of open/closed. 

 

1.4.  performance characteristics 

The device...: 

  ...is a battery-operated door/window contact  

  ...is suitable for concealed installation in door/window frames due to its design 

  ...is Z-Wave PLUS compatible & certified 

  ...supports the Z-Wave S2 standard (Security 2) 

  ...has a battery-empty warning function. 

  ...was developed for installation indoors and protected outdoor areas. 

 
 
 
 

Summary of Contents for PLMK10000

Page 1: ...nsterkontakt Wichtige Hinweise und FAQs zu diesem Produkt und weiteren Produkten finden Sie auf der Internetseite www abus com Version 1 1 Originalbedienungsanleitung in deutscher Sprache F r k nftige...

Page 2: ...ender Adresse bezogen werden ABUS Security Center GmbH Co KG Linker Kreuthweg 5 86444 Affing GERMANY Alle enthaltenen Firmennamen und Produktbezeichnungen sind Warenzeichen der jeweiligen Inhaber Alle...

Page 3: ...be pr fen Sie die technischen Daten der einzelnen Ger te Achten Sie darauf dass immer eine ausreichende Bel ftung gew hrleistet ist keine direkten W rmequellen auf das Ger t wirken kein direktes Sonne...

Page 4: ...ien verwenden Reinigen Sie das Ger t nicht mit leicht entz ndbaren Fl ssigkeiten Hinweise zur Entsorgung des Ger ts Achtung Die EU Richtlinie 2012 19 EU regelt die ordnungsgem e R cknahme Behandlung u...

Page 5: ...Funktions bersicht 7 2 1 Inklusion Inclusion Ger t einlernen 7 2 2 Montage Installation 8 2 3 Exklusion Exclusion Ger t auslernen 10 2 4 Reset Factory Reset Werkseinstellungen zur cksetzen 10 2 5 Ger...

Page 6: ...ake up Befehls Inklusion Exklusion und Reset 1 3 Funktionsprinzip Der PLMK10000 wurde zum Einsatz in Alarm und Hausautomations Systemen entwickelt die den Z Wave Funkstandard verwenden Das Ger t verf...

Page 7: ...Alternativ k nnen Sie den gesamten DSK Code den Sie auf der beiliegenden DSK Karte finden via QR Code Scan zum Gateway bertragen Bitte bewahren Sie die DSK Karte an einem sicheren Ort auf 2 Funktions...

Page 8: ...uktionen aufgeklebt werden da dies zur Einschr nkung der Reichweite f hren kann Der Magnet sollte nicht auf einer Metallfl che platziert werden Das Ger t hat eine Funkreichweite von bis zu 40 m Die Ba...

Page 9: ...platzieren Sie den Magnet ffnen und schlie en Sie das Fenster die T r um festzustellen ob Ihr Z Wave Gateway die nderungen erkennt Platzieren Sie den Sensor wieder neu falls notwendig Haben Sie die o...

Page 10: ...linkt nun 1x lang auf Wiederholen Sie den Exklusionsvorgang erneut falls dieser nicht erfolgreich war 2 4 Reset Factory Reset Werkseinstellungen zur cksetzen Platzieren Sie den runden Magneten auf den...

Page 11: ...ASIC SET gesendet Der Notification Sensor unterst tzt eine Assoziationsgruppe Gruppen Nummer Maximale Ger te bermittelter Inhalt Gruppe 1 Lifeline 1 0x01 Batterie Bericht Notification Bericht Sensor B...

Page 12: ...ontrol 0x06 Notification Events 0x16 0x17 2 Basic Bericht 0x16 0x17 2 LED Anzeige 1 byte 0 Spezifisches Ereignis Anzeige Aus 1 1 An Spezifisches Ereignis erkannt z B T r ge ffnet 3 Supervision Aktivie...

Page 13: ...nary Sensor Zwave library type Routing Slave Device Type Role type Notification sensor Reporting sleeping slave Z Wave DevKit Version 6 81 03 Default wake up interval 24 Std 4 1 Erg nzende Hinweise Di...

Page 14: ...e door window contact Important notes and FAQs about this product and other products can be found on the Internet page www abus com Version 1 1 Original operating instructions in english language Keep...

Page 15: ...MK10000 It can also be obtained at the following adress ABUS Security Center GmbH Co KG Linker Kreuthweg 5 86444 Affing GERMANY All contained company names and product names are trademarks of their re...

Page 16: ...t Please refer to the individual devices technical data for more detailed information Ensure that adequate ventilation is always guaranteed no direct sources of heat can affect the device interior dev...

Page 17: ...se chemicals Do not use flammable liquids for cleaning the device Information on device disposal Important The EU Directive 2012 19 EU regulates the proper return treatment and recycling of used elect...

Page 18: ...turers 7 2 functional overview 7 2 1 Inclusion Inclusion Teach in device 7 2 2 Assembly Installation 8 2 3 Exclusion Exclusion Teach device out 10 2 4 Reset factory reset reset factory settings 10 2 5...

Page 19: ...ering of wake up command inclusion exclusion and reset 1 3 Functionalities The PLMK10000 is designed for use in alarm and home automation systems using the Z Wave radio standard The device includes th...

Page 20: ...de found on the enclosed DSK card to the gateway via QR Code Scan Please keep the DSK card in a safe place 2 functional overview 2 1 Inclusion Teach in device Activate the inclusion mode teach in mode...

Page 21: ...of up to 40 m The battery life of the device is reduced if the radio connection to the Z Wave Gateway is not direct but via a repeater Preparation Place the sensor so that it cannot be seen A clearan...

Page 22: ...see if your Z Wave Gateway detects the changes Reposition the sensor if necessary Once you have found the optimum position mark it and remove the sensor again Make sure that the area remains clean Re...

Page 23: ...e status LED now flashes 1x long Repeat the exclusion process again if it was unsuccessful 2 4 Reset factory reset reset factory settings Place the round magnet on the upper rounded edge and remove it...

Page 24: ...p number Maximum appliances Transmitted content Group 1 Lifeline 1 0x01 Battery Report Notification Report Sensor Binary Report Basic report Device Reset Locally Notification 3 2 Notification Commands...

Page 25: ...ion Type Access Control 0x06 Notification Events 0x16 0x17 2 Basic Report 0x16 0x17 2 LED indication 1 byte 0 Specific event indication Off 1 1 On Specific event detected e g door opened 3 Activate su...

Page 26: ...ty Yes S2 Authenticated S2 Unauthenticated Z Wave Chip Generation 500 Z Wave Sensor Type Binary Sensor Zwave library type Routing Slave Device Type Role type Notification sensor Reporting sleeping sla...

Reviews: