![Abus FUMO50010 Installation Instructions Manual Download Page 5](http://html1.mh-extra.com/html/abus/fumo50010/fumo50010_installation-instructions-manual_3607330005.webp)
Dimensions (WxHxD)
130 x 155 x 42 mm
Weight
223 g (without batteries), 274 g (with batteries)
Displays
3 status LEDs
Signal strength/wireless reception range
Software version
Operating temperature
-10°C to +55°C
Environmental class
II (EN50131-1 §7, EN50131-3 §7)
Humidity
max. 94% (non-condensing)
Protection class
IP34 (indoors)
Radio frequency
868.6625 MHz
Transmission power, wireless
max. 10 mW
Wireless range
500 m outdoors
Wireless identification code
16.777.214 (224 – 2) variants
Security level
2 (EN50131-1 §6, EN50131-3 §6)
Tamper protection (detection/protection)
Typ B (EN50131-3 §8.7)
Power supply
6–15 V DC, external PSU
Backup Power Supply
2 AA alkaline batteries
(Duracell Procell MN1500, Duracell Industrial ID1500, Energizer E91)
'Low battery' error message
< 2.7 V ('low battery' threshold)
Power consumption
22 (TX), 17 (RX) mA @ 12V DC, nominal
20 (TX), 15 (RX) mA @ 13,8V DC, nominal
48 (TX), 38 (RX) mA @ 5V DC (USB), nominal
50 (TX), 40 (RX) mA @ 3V DC (Batterien), nominal
Voltage monitoring
During operation with an external power supply, a fault report is sent
to the alarm control panel as soon as this is interrupted. The wireless
repeater is then automatically powered by the batteries. The corresponding
notification on the alarm control panel informs the user about this. The
batteries are permanently monitored. If the voltage is below the lower
threshold of 2.7 V, a fault report is sent to the alarm control panel and the
user is informed.
Type of power supply
Type B (50131-1 §9 and 50131-6 §4.1)
external power supply via power supply unit and batteries inserted
as a backup power supply
Power supply compliant with EN50131-1:2006+A1:2009 9.2 and EN50131-6 if
installed correctly together with Secvest Wireless Alarm System FUAA50xxx
Conformity
The device is compliant with EN 50131-1, EN50131-3:2009, EN50131-5-3 and
EN50131-6 security level 2 if installed correctly together with Secvest Wireless
Alarm System FUAA50xxx.
EU Directives
RED: 2014/53/EU, EMC: 2014/30/EU, RoHS: 2011/65/EU WEEE: 2012/19/EU, ErP:
2009/125/EC, Low Voltage: 2014/35/EU, General Safety: 2001/95/EC
TECHNICAL DATA