15
Dimensions
80 x 108 x 43 mm (HxWxD)
Weight
140 g
HF immunity
10 V/m
Power supply
3.0 V DC (lithium CR2 battery)
“Low battery” error
message
< 2.4 V
Frequency
868.6625 MHz
HF transmission power 10 mW (antenna input)
Tamper monitoring
Yes
Supervision monitoring
Every 4 minutes
Housing material
ABS
Subject to alterations and errors.
Position
The detector has a sensor that monitors the entire room
(360°), though it should not directly face the area to be
monitored. It is designed for installation on walls and
ceilings.
Ideally, the detector should be installed on the wall opposite
the window. The ceiling or side walls are also suitable
locations.