13
5. Confirm the successful learning procedure on the wireless
alarm centre.
6. Define which partition should be used by the internal siren.
Select the partition using the jumper.
Acoustic signal tones
The internal siren can generate a whole series of acoustic signal
tones. These are similar to the signal tones of the wireless alarm
centre. In the event of an alarm, the internal piezo signaller of the
internal siren is activated simultaneously.
The following table gives an overview of the signal tones and their
meaning.
Signal tone
Meaning
Short beep
(beep)
The system is faulty and the centre cannot
be activated.
Interrupted beeps
(beep…beep…beep)
A zone was opened during the exit delay
time. This must be closed before the delay
time expires.
Long, continuous beep
(beeeeeeeeeeeep)
The exit delay time is active. All zones are
closed, the centre is activated after the delay
time expires.
Short, interrupted beeps
(beepbeepbeepbeep)
The entry delay time is active.
Beeps at different pitch
•
The centre was successfully activated.
•
The learn signal was received and
stored.
•
When exiting the installer menu.
•
Door chime (when selected under zone
attributes).
Jumper connections
“ALARM ONLY”: When this jumper is attached in 12 V operation,
then only the alarm tones of the internal siren are emitted. When
this jumper is not attached, then the information tones of the alarm
centre are also emitted.