39
1. Loudspeaker
2. Tamper
contact
3. Microphone
4. Tamper
loop
5. Inputs
A-D
6. Jumper for trigger polarity
7. Telephone
connection
8. Power supply 12 V/0 V DC and output
9. Jumper for the factory settings reset
7. Connections
IMPORTANT
:
Make sure that the power supply is switched off before wiring!
7.1 General
information
Connection Description
TRIG A
When this input is triggered, the device begins transmission of
message A.
TRIG B
When this input is triggered, the device begins transmission of
message B.
TRIG C
When this input is triggered, the device begins transmission of
message C.
ABORT / D
When this input is triggered, the device begins transmission of
message D.
This input can also be used to abort dialling procedures (see
chapter 10.8 “Abort function”).
TAMP
These two connector clamps can be connected to the tamper
zone of an alarm centre. If the device housing is opened, the
sabotage loop to the centre is interrupted and a tamper alarm
is triggered.