background image

22 Revised 

10/2014 

4.

 

Systems with UV

 Check flow coming out of the UV filter, if 

flow is reduced there is an obstruction in the UV housing. 
Unplug the UV before checking for obstructions 

5.

 

Remove the waste water (yellow) line from the membrane 
housing (a capillary flow restrictor is installed in the line) and 
check water flow; there should be a steady flow of water. If 
there is no water flow and water is reaching the membrane, 
the membrane is fouled and needs replaced.  

6.

 

Check flow after the flow restrictor. Flow should be reduced, 
but should still be coming out in a steady stream. If flow is the 
same or if flow is completely gone, the flow restrictor is 
defective and needs to be replaced. 

7.

 

Check the line coming from the check valve on the membrane 
to the auto shut off valve (refer to the connection diagram if 
you are unsure where the check valve is). You should get a 
steady drip or a slow stream. If there is no flow, remove the 
check valve (simply unscrew counterclockwise) and test again. 
If flow is achieved by removing the check valve, replace the 
defective check valve. If removing the check valve does not 
solve the problem, either your pressure is too low (common on 
new installations, 40psi minimum is required) or the 
membrane is fouled (more common on older systems). 

8.

 

Check line connecting the auto shut off to the T-fitting on the 
next filter (refer to connection diagram if you are unsure which 
filter is next). Flow should be the same here as it was coming 
out of the membrane. If not, the auto shut off valve is stuck 
and not allowing water through, replace the auto shut off 
valve. 

9.

 

Ensure tank ball valve closed and check the flow of water after 
each of the inline filters. (Inline filters may include post filter, 
pH filter, and alkaline filter, depending on your system.) 
Remove the line after each filter and check the water flow. 
Flow should be close to the same through each filter as it was 
coming from the auto shut off valve. If significantly reduced 
flow is found after one of the filters, replace the filter. 

10.

 

Remove the line connected to the faucet (blue) and check flow 
there. If flow is restricted, replace the tubing between the 
final filter on the system and the faucet. If flow through the 
line is fine but there is no water from the faucet, replace the 
faucet. 

©Abundant Flow Water Systems, Inc 

Contents 

Important Information ........................................................................ ii

 

Maintenance Log: .................................................................................. ii

 

Parts List .................................................................................................. ii

 

Connection Diagram for Zoi RO Systems ..................................... iii

 

Pre-installation Preparation .............................................................. 1

 

Brief Technical Summary of the Filtration Process ...................... 1

 

Water Purification Summary: ............................................................ 1

 

System Maintenance Summary: ....................................................... 2

 

Pre-installation Check List ................................................................. 2

 

Parts Checklist ..................................................................................... 3

 

System Installation ............................................................................... 4

 

Filter Upgrade Installation ................................................................ 4

 

Faucet Installation .............................................................................. 5

 

Drilling a hole for the faucet ......................................................... 5

 

Mounting the Faucet: ..................................................................... 6

 

Storage Tank: ....................................................................................... 7

 

To Prepare the Tank: ...................................................................... 7

 

Feed Water Installation: .................................................................... 7

 

Flex line Instructions ...................................................................... 8

 

Copper Instructions ........................................................................ 8

 

Drain Saddle Installation:................................................................... 8

 

To install: ........................................................................................... 9

 

Connecting the system: ....................................................................... 9

 

Feed Water Line – RED .................................................................... 10

 

Tank Line – CLEAR ............................................................................  10

 

Faucet (Good Water) Line – BLUE ................................................. 10

 

Drain (Waste Water) Line – YELLOW............................................ 10

 

Example of Connected System ..................................................... 11

 

Optional Ice Maker Kit Installation ............................................... 11

 

System Start Up: ................................................................................. 11

 

Preparing the system for use: ....................................................... 12

 

System Maintenance .........................................................................  13

 

Filters: ................................................................................................. 13

 

To change filters: .............................................................................. 13

 

O-rings: ............................................................................................... 15

 

Housings .............................................................................................  16

 

UV Filter: ............................................................................................ 16

 

To change the lamp: .................................................................... 16

 

Summary of Contents for Zoi DFK-Alpha

Page 1: ...return items without a RMA and contact us with details about the return will be responsible for return shipping regardless of warranty covered defects LIMITATIONS AND EXCLUSIONS Abundant Flow Water w...

Page 2: ...transformers clips check valves flow restrictors ball valves storage tanks faucets adapters drain valves filter housing wrenches tubing and accessories included in your original order What Does This W...

Page 3: ...s IN OUT Ultra Violet UV Filter Connects to UV Transformer Water can ow either direction depending on install Solid Blue with a stem on each end RO Membrane YELLOW BLACK Wastewater Line Clamps around...

Page 4: ...alve Defective Auto Shut Off Replace auto shut off valve Defective Flow Restrictor Replace flow restrictor Obstruction In Line Ensure valves open no kinks in lines Trace flow of water Tank Not Holding...

Page 5: ...not allowing water through replace the auto shut off valve 9 Ensure tank ball valve closed and check the flow of water after each of the inline filters Inline filters may include post filter pH filter...

Page 6: ...om fitting Turn feed water valve back on ensuring it is fully open before checking flow Repeat this process with each step until the problem is found 1 Check feed water line red connected to the inlet...

Page 7: ...recommended to 2014 Abundant Flow Water Systems Inc 1 Pre installation Preparation IMPORTANT Read through the entire instruction manual before beginning installation Abundant Flow Water is not respons...

Page 8: ...have room for everything and plan room for future filter changes 4 Familiarize yourself with the quick connect fittings Your system uses quick connect fittings There is a collet ring at the end of th...

Page 9: ...ousing some housings have 2 and screw the membrane housing cap back onto the housing 10 Push the tubing back into the fitting on the membrane cap 11 If the filters need changed now is a good time to d...

Page 10: ...ter Systems Inc 17 handle is at a 90 angle to the tubing when the handle is NOT parallel to the tubing 3 Open the faucet to release any remaining pressure 4 Unscrew the cap on the UV filter and carefu...

Page 11: ...hten until snug making sure to not over tighten which would cause the filter to crack or could strip out the threads 3 Now we will install the filter s in the order shown by the diagram on the back of...

Page 12: ...filter paying careful attention to the direction of flow as indicated on the filter and ensuring the new filter is installed in the same direction as the old filter Do this with each inline filter yo...

Page 13: ...rs in the housings have been changed it is time to change the inline filter s the post filter as well as the pH Mineral filter Alkaline filter if the system 2014 Abundant Flow Water Systems Inc 7 may...

Page 14: ...he waste water from your system down the drain Depending on where the saddle is located you may hear water running down the drain when the system is making water this is normal If the sound is annoyin...

Page 15: ...his flushes the system removing any preservatives from the membrane and cleaning off the filters 10 Repeat steps 8 9 at least once ensuring the system is flushed and ready to use 11 The system is now...

Page 16: ...the end of the tube Push the tube into the faucet shank and secure by tightening the line nut Refer to Figure 1 Drain Waste Water Line YELLOW PRE CONNECTED Connects from the membrane to the drain sad...

Reviews: