AFW RO System Manual
[7]
Revised 9/09
©Abundant Flow Water System, Inc. 2009
Feed Water Line - RED:
Connects from the feed water ball valve (connected to
the “IN” on the first (clear) filter housing with the white sediment filter in it) to the
angle ball valve on the feed water adapter. To connect, place the nut on the line,
push the line over the barb on the angle valve and tighten the nut.
Faucet (Product Water) Line - BLUE:
Connects from the T-fitting on the OUT
side of the DI filter (the last filter on the bottom) to the faucet shank. To use the
compression fitting that comes with the faucet, slide the nut over the tube,
followed by the ferrule, placing the insert into the end of the tube, push the tube
into the faucet shank and secure by tightening the line nut. (Refer to Figure 1 for help)
Tank Line - CLEAR:
Connects from the T-fitting on the inline post to the ball valve
on the tank. To attach, simply push the tubing firmly into the fitting, the tank valve
is in the open position when the handle is in line with the tubing.
Drain (Waste Water) Line - YELLOW:
Connects from the flow restrictor (white
cylinder about 3” long, located behind the membrane) to the drain saddle valve.
To connect, simply push tubing firmly into the fitting.
Example of Connected System
(System may differ from the one shown)
(RED)