5.2 

Every 3 Months 

Visually inspect the ABT 4550 series gauges for signs of damage. If necessary, contact your 
local distributor for help. 

5.3 

Annual 

The  ABT  4550  series  gauges  must  be  returned  annually  for  re-calibration  to  ensure 
measurements are within specification. 
The condition of all components will be checked at this time and replaced as required. 

5.4 

Replacing the PP3 Batteries 

To replace the PP3 batteries, carefully remove the battery compartment from the front of the 
gauge as shown in Figure 7. Visually inspect the gasket for signs of wear/damage and replace 
if necessary, contact your local distributor for help. 

 

Figure 3 - Battery Replacement

 

Summary of Contents for ABT 4550 Series

Page 1: ...ABT 4550 Prism Track Gauge Instruction Manual ...

Page 2: ... 1 0 Index 2 2 0 Overview 3 3 0 Technical Specification 4 4 0 Functionality 4 4 1 Track Gauge 4 4 2 Cant 5 5 0 Maintenance 5 5 1 User Advice 5 5 2 Every 3 Months 6 5 3 Annual 6 5 4 Replacing the PP3 Batteries 6 ...

Page 3: ...are suitable for use in areas of 3rd and 4th rail electrification The ABT4550 is available in both imperial and metric versions for multiple track widths The standard mushrooms measure 14mm below the top of the rail TOR alternative P points should be specified when an order is placed Super Elevation is measured electronically and is shown on an LCD display The expected battery life for normal aver...

Page 4: ...or rail gauge is the distance between the inner sides of the heads of the two stock rails as shown in Figure 1 Weight 3 2Kg Size 1660mm x 135mm x 150mm Cant Range 199mm Accuracy 1mm Resolution 0 1mm Gauge Range 1410 1490mm Accuracy 1mm Resolution 1mm Dependent upon Gauge Type Gauge Size Gauges manufactured in compliance with NR L3 TRK 4900 Track Gauge Specification Figure 1 Track Gauge Rail Gauge ...

Page 5: ...e gauge is settled The display will turn off within a minute of pressing the button 5 0Maintenance 5 1 User Advice The ABT 4550 series gauges are a piece of precision measurement equipment Whilst it has been designed for use in an engineering environment due care should be taken not to cause damage to the equipment when in operation storage or transit Excessive trauma to the moving parts of the ga...

Page 6: ...sure measurements are within specification The condition of all components will be checked at this time and replaced as required 5 4 Replacing the PP3 Batteries To replace the PP3 batteries carefully remove the battery compartment from the front of the gauge as shown in Figure 7 Visually inspect the gasket for signs of wear damage and replace if necessary contact your local distributor for help Fi...

Reviews: